by Jim Jackson | Jun 10, 2019 | iMistAway
The iMist gateway is connected to the internet but it is not communicating with the node on the misting unit. Potential Cause: The gateway has lost the ID of the node on the misting unit. The gateway or node has failed. Troubleshooting: To confirm the issue, open the...
by Jim Jackson | May 11, 2019 | Controller & Remote, Gen 1.3 - Troubleshooting
If the display on the Gen 1.3 controller is blank, and you are certain there is power to the outlet, either the fuse protecting the controller has blown due to a power surge, or a component in the misting unit is shorted, or the controller has otherwise failed. A...
by Jim Jackson | May 11, 2019 | Controller & Remote, Gen 3 - Troubleshooting
If the display on the Gen 3/3+ controller is blank, and you are certain there is power to the outlet, either the fuse protecting the controller has blown due to a power surge, or a component in the misting unit is shorted, or the controller has otherwise failed. A...
by Jim Jackson | Apr 25, 2019 | Specs, Safety & Warranty
What is iMistAway? iMistAway is a technology that enables monitoring and management of MistAway’s mosquito misting systems over the internet. It allows MistAway’s dealers to provide a superior level of service to their customers by enabling activities like...
by Jim Jackson | Apr 21, 2019 | Nozzle Circuit
iMist has identified that the last AFR (average flow rate) of the nozzle circuit is less than 30 ml/min. If a nozzle circuit is installed correctly, and the nozzles are not fouled, the average flow rate should be in the 40 – 50 ml/minute range. Below about 30...