by Homer Jon Young | Dec 31, 1969 | Gen 3 - Troubleshooting
What is ERR0? ERR0 is displayed when the controller detects that the float switch did not drop during the previous mist cycle. Either the solution level in the batch tank did not drop enough for the float to drop, or The solution level dropped, but there is a problem...
by Homer Jon Young | Dec 31, 1969 | Gen 3 - Troubleshooting
ERR2 is displayed when the batch tank fill volume is significantly less than expected. ERR2 overlaps with other error codes and should be switched OFF. Switch ERR2 to OFF position: SETUP menu, select ERR2 Switch to OFF using arrow...
by Homer Jon Young | Dec 31, 1969 | Gen 3 - Troubleshooting
What is ERR4? ERR4 is displayed when the batch tank took too much time to fill after the previous mist cycle. Most Common Cause: Faucet supplying water to the unit has been shut off. Note: If faucet is shut off – causing ERR4 – and then turned back on,...
by Homer Jon Young | Dec 31, 1969 | Gen 3 - Troubleshooting
What is ERR5? ERR5 is displayed when the batch tank volume exceeds its maximum. Most Common Cause: The unit has a Brass flow meter, but the unit has been inadvertently set up in the controller to accept the input of a Plastic flow meter (used in older systems, now...
by Homer Jon Young | Dec 31, 1969 | Gen 3 - Troubleshooting
What is ERR6? ERR6 is displayed when the flow meter reading is zero after a FILL routine Most Common Cause: Flow meter is either clogged or failed. Other Potential Causes: Float switch is stuck in the up position at the end of the mist (due to buildup of residue on...