by Homer Jon Young | Dec 31, 1969 | Gen 1.3 - Troubleshooting, Gen 3 - Troubleshooting
Potential Causes: System Mode is set to OFF or REM (or ON) and should be set to AUTO EVERYDAY or AUTO-CUSTOM. See Controller: Setting System Mode There are no AUTO MIST cycles defined. See Controller: Setting AUTO MIST Cycles The controller has calculated that the...
by Homer Jon Young | Dec 31, 1969 | Controller & Remote, Gen 1.3 - Troubleshooting, Gen 3 - Troubleshooting
Unit displays NOZ00 and will not mist. Cause: Nozzle count in the SET-Up Menu is not set. Clear by pressing and holding the Red MENU/STOP button for 5 seconds. Press the Red MENU/STOP button to display the triangular cursor, ►, by DAY/TIME position on left side of...
by Homer Jon Young | Dec 31, 1969 | Gen 1.3 - Troubleshooting
This article covers how to diagnose the issue of nozzles not misting on a Gen 1.3 Drum unit, as well as going over the troubleshooting/repair process to determine the failed component and ultimately fix it. See Gen 1.3: Controller displays “MIST”,...
by Homer Jon Young | Dec 31, 1969 | Gen 1.3 - Troubleshooting
Displayed Level is greater than Actual Level Possible Causes: Actual flow rate is greater than the controller Target Flow Rate (NFR entered into the DATA Menu) – which may also point to a leak or siphon in the nozzle circuit. Actual nozzle count is greater than...
by Homer Jon Young | Dec 31, 1969 | Gen 1.3 - Troubleshooting
This post will detail the definition of an ERR3, as well as the common and potential causes of the solution. It will also delve into simple troubleshooting methods that can be used to diagnose and treat the issue. What is ERR3? ERR3 is displayed when the...