by Homer Jon Young | Dec 31, 1969 | Controller & Remote, Gen 1.3 - Troubleshooting, Gen 3 - Troubleshooting
Unit displays NOZ00 and will not mist. Cause: Nozzle count in the SET-Up Menu is not set. Clear by pressing and holding the Red MENU/STOP button for 5 seconds. Press the Red MENU/STOP button to display the triangular cursor, ►, by DAY/TIME position on left side of...
by Homer Jon Young | Dec 31, 1969 | Concentrates, Gen 1.3 - Routine Service, Gen 3 - Routine Service
You will need to enter these factors into the calculator: System with Gen 1.3 Drum unit: Formulation name (or % concentration of active ingredients in concentrate) Target concentration % of active ingredients in the mist Capacity of the drum (in gallons) Solution...
by Homer Jon Young | Dec 31, 1969 | Gen 1.3 Repairs
The primary cause of failure in the remote receiver is water entering the connection with the CAT 5 cable. When replacing the remote receiver, we advise also replacing the receiver cable and antenna. Time: 5 minutes Tools: Phillips screwdriver Parts: Gen 1.3/3...
by Homer Jon Young | Dec 31, 1969 | Controller & Remote
Setting System Mode With the display showing day, time and level, press Green ► button to position the ▲ at top of display pointing to active System Mode. OFF – daily agitation cycle only ON – remote and manual, but no programmed mist AUTO Everyday –...
by Homer Jon Young | Dec 31, 1969 | Specs, Safety & Warranty
Basic Functionality MistAway’s Tankless Misting Unit, Gen III+, is a batch processing unit that precisely mixes water from a faucet and concentrated insecticide from a cartridge in a batch tank and then atomizes it through an installed nozzle circuit to...