<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Gen 1.3 Specs Safety and Warranty Archives - TechSelfHelp</title>
	<atom:link href="https://help.mistaway.com/tag/gen-1-3-specs-safety-and-warranty/feed/" rel="self" type="application/rss+xml" />
	<link>https://help.mistaway.com/tag/gen-1-3-specs-safety-and-warranty/</link>
	<description>MistAway TechSelfHelp</description>
	<lastBuildDate>Mon, 02 Feb 2026 20:27:03 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0.2</generator>

<image>
	<url>https://help.mistaway.com/wp-content/uploads/2026/02/cropped-MistAway-Help-Logo-32x32.png</url>
	<title>Gen 1.3 Specs Safety and Warranty Archives - TechSelfHelp</title>
	<link>https://help.mistaway.com/tag/gen-1-3-specs-safety-and-warranty/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Warranty</title>
		<link>https://help.mistaway.com/warranty/</link>
		
		<dc:creator><![CDATA[Homer Jon Young]]></dc:creator>
		<pubDate>Thu, 01 Jan 1970 00:00:00 +0000</pubDate>
				<category><![CDATA[Specs, Safety & Warranty]]></category>
		<category><![CDATA[Gen 1.3 Specs Safety and Warranty]]></category>
		<category><![CDATA[Gen 3 Specs Safety and Warranty]]></category>
		<guid isPermaLink="false">https://help.mistaway.com/warranty/</guid>

					<description><![CDATA[<p>MistAway Systems Inc. (MSI) warrants this Product,&#160; the MistAway Drum-Based&#160; Misting Unit Gen 1.3, or the Tankless Misting Unit Gen 3, to be free from defects in material and workmanship as follows: For a period of one (1) year from the date of original&#160;purchase (whether or not actual use begins on that date), MSI will [&#8230;]</p>
<p>The post <a href="https://help.mistaway.com/warranty/">Warranty</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>
<span><span>MistAway Systems Inc. (MSI) warrants this Product,&nbsp; the MistAway Drum-Based&nbsp; Misting Unit Gen 1.3, or the Tankless Misting Unit Gen 3, to be free from defects in material and workmanship as follows:</p>
<p>For a period of one (1) year from the date of original&nbsp;purchase (whether or not actual use begins on that date), MSI will repair or replace defective parts, with new or refurbished parts, at its option, at no charge.&nbsp; This warranty does not include labor or other costs incurred for diagnosing, removing, installing, shipping, servicing or handling of either defective parts or replacement parts.</p>
<p>This warranty applies solely to equipment supplied by MSI and is in lieu of all other warranties, expressed or implied. No person, agent, dealer, or distributor is authorized or empowered to give any other warranty or to assume any other liability on behalf of MSI</p>
<p><strong>Warranty Conditions:</strong></span></span><br />
&nbsp;</p>
<div><span><span>&bull;This warranty is extended only to the original Purchaser and is not transferable.</span></span></div>
<div><span><span>&bull;A purchase receipt or other proof of date of original purchase will be required before warranty service is rendered.</span></span></div>
<div><span><span>&bull;Installation, use, care and maintenance must be normal and in accordance with instructions contained in the operating manual and MSI&rsquo;s service information.&nbsp; Failure to do so shall void this warranty.</span></span></div>
<div><span><span>&bull;All claims for failure to conform to specifications or defects in material or workmanship under this warranty must be made promptly after discovery and, in any event, must be received by MSI not more than one year after the original purchase date.</span></span></div>
<div><span><span>&bull;MSI reserves the right to inspect the equipment prior to any decision involving a warranty claim.</span></span></div>
<div><span><span>&bull;MSI reserves the right to make warranted repairs at either the installed site or at MSI&rsquo;s location in Houston, TX.&nbsp; If MSI opts for repair at its own location, the Purchaser is responsible for shipping the item to MSI&rsquo;s Houston location at its expense.</span></span></div>
<p>
<span><span><strong>Manufacturer&rsquo;s obligation under the warranty shall not apply to:</strong></span></span><br />
&nbsp;</p>
<div><span><span>&bull;Any equipment, which has been damaged by negligence, misuse, abuse, neglect and/or improper adjustment, accident, vandalism, acts of God, acts of war, whether declared or undeclared, improper application, or any other contingency beyond the control of MSI</span></span></div>
<div><span><span>&bull;Cosmetic damage</span></span></div>
<div><span><span>&bull;Damage in transit</span></span></div>
<div><span><span>&bull;Failures caused by products not supplied by MSI</span></span></div>
<div><span><span>&bull;Failures, which result from faulty installation, set-up adjustments, improper operation, power line surge, improper voltage supply or damage from lightning</span></span></div>
<div><span><span>&bull;Any equipment that has been repaired or altered without authorization from MSI or in a manner inconsistent with such authorization</span></span></div>
<div><span><span>&bull;Any unit that has not been maintained in accordance with the operator&rsquo;s manual</span></span></div>
<div><span><span>&bull;Normal wear on any item or piece of equipment</span></span></div>
<div><span><span>&bull;Lost items</p>
<p>The foregoing is MSI&rsquo;s only obligation and Purchaser&rsquo;s exclusive remedy for breach of warranty.&nbsp; Purchaser&rsquo;s failure to submit a claim as provided above shall specifically waive all claims for damages or other relief, including but not limited to claims based on latent defects.&nbsp; In no event shall Purchaser be entitled to special, direct, indirect, incidental, exemplary or consequential damages, expenses, injury, lost profits, lost savings, business interruption, loss of business information, or any other pecuniary loss arising out of the use of or inability to use the equipment.&nbsp; In any case, MSI&rsquo;s entire liability shall be limited to the amount Purchaser actually paid for the item.</p>
<p>Except as modified in writing signed by both parties, this warranty is and shall remain the complete and exclusive agreement between the parties with respect to warranties, superseding all prior agreements, oral or written, and all other communications between the parties relating to the subject matter of this agreement.</span></span></div>
<p>The post <a href="https://help.mistaway.com/warranty/">Warranty</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Important Safety Instructions</title>
		<link>https://help.mistaway.com/important-safety-instructions/</link>
		
		<dc:creator><![CDATA[Homer Jon Young]]></dc:creator>
		<pubDate>Thu, 01 Jan 1970 00:00:00 +0000</pubDate>
				<category><![CDATA[Specs, Safety & Warranty]]></category>
		<category><![CDATA[Concentrate Safety]]></category>
		<category><![CDATA[Gen 1.3 Specs Safety and Warranty]]></category>
		<category><![CDATA[Gen 3 Specs Safety and Warranty]]></category>
		<guid isPermaLink="false">https://help.mistaway.com/important-safety-instructions/</guid>

					<description><![CDATA[<p>To Protect Against Accidental Exposure to Insecticide Permitted Insecticides and Handling Use only insecticides that are labeled for use in automated misting systems, and use only as described in the label. Insecticides that state “Not for use in outdoor residential misting systems” may not be used under any circumstances. Once insecticide has been introduced, ensure [&#8230;]</p>
<p>The post <a href="https://help.mistaway.com/important-safety-instructions/">Important Safety Instructions</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong><span class="fontred">To Protect Against Accidental Exposure to Insecticide </span></strong></p>
<p>Permitted Insecticides and Handling</p>
<ul>
<li>Use only insecticides that are labeled for use in automated misting systems, and use only as described in the label.</li>
<li>Insecticides that state “Not for use in outdoor residential misting systems” may not be used under any circumstances.</li>
<li>Once insecticide has been introduced, ensure 6” air gap between hose and drum bung is maintained when filling.</li>
<li>Insecticide label and dilution statement should be securely attached to the unit reservoir in a weatherproof pouch.</li>
<li>Strictly follow label instructions regarding storage and disposal of insecticide and container.</li>
</ul>
<p><strong>Nozzle Circuit Installation:</strong></p>
<ul>
<li>The nozzle circuit should be configured and installed so that insecticide does not drift off the property.</li>
</ul>
<div>
<ul>
<li>Nozzles should be directed to spray towards the target area and away from swimming pools, water bodies, or eating and cooking areas.</li>
</ul>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-9500 size-full" src="https://help.mistaway.com/wp-content/uploads/1969/12/warning.png" alt="" width="325" height="51" srcset="https://help.mistaway.com/wp-content/uploads/1969/12/warning.png 325w, https://help.mistaway.com/wp-content/uploads/1969/12/warning-300x47.png 300w" sizes="(max-width: 325px) 100vw, 325px" /></p>
<p><strong>Using the Unit</strong></p>
<ul>
<li>Do not allow the unit to mist in the presence of people, pets or food.</li>
<li>Unit must be configured, installed and operated so that any insecticide application complies with all label directions, including application rate and prohibitions against offsite drift.</li>
<li>The unit reservoir and controller should be locked.</li>
<li>Unit and remote transmitter should be secured against access by children.</li>
<li>DIP Switches on remote transmitter should be repositioned (from factory setting) to ensure that another transmitter will not activate unit.</li>
<li>If a leak or siphon in nozzle circuit is suspected, discontinue use of unit until it is repaired.</li>
</ul>
<ul>
<li>Unit must never be used for cooling.</li>
</ul>
<p><strong><span class="fontred">To Protect Against Fire or Electric Shock </span></strong></p>
<ul>
<li>Ensure unit is positioned where it is free from flooding or exposure to irrigation system spray.</li>
<li>Unit must be plugged into electrical outlet with ground fault interrupt protection. (GFI/GFCI)</li>
<li>Extension cord must not be used.</li>
<li>Disconnect unit from power source if replacing components.</li>
<li>Replace fuses only with those of equivalent value.</li>
</ul>
</div>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-9506" src="https://help.mistaway.com/wp-content/uploads/1969/12/electrical-shock-hazard.png" alt="" width="296" height="192" /></p>
<p>The post <a href="https://help.mistaway.com/important-safety-instructions/">Important Safety Instructions</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Gen 1.3:  Functionality and Capacity</title>
		<link>https://help.mistaway.com/gen-1-3-functionality-and-capacity/</link>
		
		<dc:creator><![CDATA[Homer Jon Young]]></dc:creator>
		<pubDate>Thu, 01 Jan 1970 00:00:00 +0000</pubDate>
				<category><![CDATA[Specs, Safety & Warranty]]></category>
		<category><![CDATA[Gen 1.3 Specs Safety and Warranty]]></category>
		<guid isPermaLink="false">https://help.mistaway.com/gen-1-3-functionality-and-capacity/</guid>

					<description><![CDATA[<p>Base Functionality &#160; MistAway&#8217;s Drum-Based Misting Unit, Gen 1.3, is designed to atomize a dilute insecticide (typically contained in a 55 gallon drum) through an installed nozzle circuit to control mosquitoes and other annoying insects. The capacity of the unit is dependent on the configuration of the nozzle circuit.&#160; A practical field maximum for one [&#8230;]</p>
<p>The post <a href="https://help.mistaway.com/gen-1-3-functionality-and-capacity/">Gen 1.3:  Functionality and Capacity</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<div><strong><span><span>Base Functionality</span></span></strong><br />
&nbsp;</div>
<ul>
<li><span><span>MistAway&rsquo;s Drum-Based Misting Unit, Gen 1.3, is designed to atomize a dilute insecticide (typically contained in a 55 gallon drum) through an installed nozzle circuit to control mosquitoes and other annoying insects.</span></span></li>
<li><span><span>The capacity of the unit is dependent on the configuration of the nozzle circuit.&nbsp; A practical field maximum for one zone is about&nbsp; 75 nozzles (some in parallel) connected by&nbsp;750 feet of tubing.</span></span></li>
<li><span><span>The unit may be programmed to mist up to 24 times daily, with each mist cycle having its own independent duration.&nbsp; A typical program will consist of 2 to 3 mist cycles per day, each with a 45 &ndash; 60 second duration, for a daily total of 90 &ndash; 180 seconds.</span></span></li>
<li><span><span>The unit will also mist in response to a signal from a handheld remote transmitter for a duration programmed by the user.</span></span></li>
</ul>
<p>
<strong><span><span>Optional Equipment and Functionality</span></span></strong><br />
&nbsp;</p>
<ul>
<li><span><span><u>Agitating Valve:</u>&nbsp; Each mist (including remote mists) will be preceded by an agitation cycle that will ensure thorough mixing of the drum contents prior to misting.&nbsp; In addition, there is a capability to program a once-daily agitation that is independent of any programmed or remote mist.&nbsp; The agitating valve also eliminates the possibility of a siphon emptying the drum contents.</span></span></li>
<li><span><span><u>Leak Detection:</u>&nbsp; In the event of a leak in the misting nozzle circuit, this option will shut-off the unit until the leak can be repaired.</span></span></li>
<li><span><span><u>Electronic Anti-Siphon Valve:</u>&nbsp; For units without agitation, addition of this valve eliminates the possibility of a siphon.</span></span></li>
<li><span><span><u>Wind Sensor:</u> Sensor input will inhibit a programmed mist if the wind speed is higher than a user-defined limit for a 5 minute period following the scheduled mist.</span></span></li>
<li><span><span><u>Zone Kit:</u>&nbsp; Kit will enable the unit to either independently manage areas with two different application schedules or effectively double the protected area that the unit would otherwise support.</span></span></li>
<li><span><span><u>iMistAway Module:</u> Allows the unit to be remotely monitored and controlled via an Internet connection.</span></span></li>
</ul>
<p>The post <a href="https://help.mistaway.com/gen-1-3-functionality-and-capacity/">Gen 1.3:  Functionality and Capacity</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Gen 1.3:  Schematic and Components</title>
		<link>https://help.mistaway.com/gen-1-3-schematic-and-components/</link>
		
		<dc:creator><![CDATA[Homer Jon Young]]></dc:creator>
		<pubDate>Thu, 01 Jan 1970 00:00:00 +0000</pubDate>
				<category><![CDATA[Specs, Safety & Warranty]]></category>
		<category><![CDATA[Gen 1.3 Specs Safety and Warranty]]></category>
		<guid isPermaLink="false">https://help.mistaway.com/gen-1-3-schematic-and-components/</guid>

					<description><![CDATA[<p>The operations of the Gen 1.3 are managed by a digital controller and a number of electro-mechanical components.  Information about mist schedules, duration, and agitating the insecticide are entered into the controller by the user. Components &#8211; Mounted to Chassis on Drum Lid Digital Controller – accepts user input, displays unit operating mode and status, [&#8230;]</p>
<p>The post <a href="https://help.mistaway.com/gen-1-3-schematic-and-components/">Gen 1.3:  Schematic and Components</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The operations of the Gen 1.3 are managed by a digital controller and a number of electro-mechanical components.  Information about mist schedules, duration, and agitating the insecticide are entered into the controller by the user.</p>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-9504 size-full" src="https://help.mistaway.com/wp-content/uploads/1969/12/schematic2.png" alt="" width="415" height="564" srcset="https://help.mistaway.com/wp-content/uploads/1969/12/schematic2.png 415w, https://help.mistaway.com/wp-content/uploads/1969/12/schematic2-221x300.png 221w, https://help.mistaway.com/wp-content/uploads/1969/12/schematic2-300x408.png 300w" sizes="(max-width: 415px) 100vw, 415px" /><br />
<strong>Components &#8211; Mounted to Chassis on Drum Lid </strong></p>
<ul>
<li><u>Digital Controller </u>– accepts user input, displays unit operating mode and status, controls electromechanical components.</li>
<li><u>Remote Receiver &amp; Antenna </u>– receives signal from handheld remote transmitter</li>
<li><u>Pump &amp; Motor </u>– atomizes drum contents through nozzle circuit.  Pump pressure typically set to 240 psi.</li>
<li><u>Agitating Valve (optional)</u> – One path through the valve routes fluid to the nozzle circuit.  The other path recirculates fluid in the drum through j-tube mixing assembly.</li>
</ul>
<div>
<ul>
<li><u>Plastic Housing &amp; Cover </u>– protects components from the elements.  The cover may be locked to the housing to secure access to the controller.  The housing contains ports to the nozzle circuit tubing as well as to an optional Zone Kit.  On units with an agitating valve, a pressure gauge is mounted into the plastic housing.</li>
</ul>
<p><strong>Components &#8211; Inside Drum</strong></p>
<ul>
<li><u>Pump Intake Line and Filter </u>– Pump intake positioned near bottom of drum.  Filter ensures debris is not drawn into pump and nozzle circuit.</li>
<li><u>J-tube Mixing Assembly (on units with optional Agitating Valve)</u>  – To ensure thorough mixing, during agitation, fluid is pushed through a j-shaped tube assembly at the bottom of the drum.</li>
</ul>
<div>
<ul>
<li><u>Auto-Drain Valve </u>– ensures rapid increase in nozzle circuit pressure on pump startup and rapid decrease on shutdown.</li>
</ul>
<p><strong>Other Components </strong></p>
<ul>
<li><u>Remote Transmitter </u>– 3-button remote enables the user to start a mist, stop a mist and skip the next scheduled mist.</li>
<li><u>Unit Cover </u>– Weatherproof fabric cover provides protection of the unit from the elements.</li>
</ul>
</div>
</div>
<p>The post <a href="https://help.mistaway.com/gen-1-3-schematic-and-components/">Gen 1.3:  Schematic and Components</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Misting Unit Spec Sheets</title>
		<link>https://help.mistaway.com/misting-unit-spec-sheets/</link>
		
		<dc:creator><![CDATA[Homer Jon Young]]></dc:creator>
		<pubDate>Thu, 01 Jan 1970 00:00:00 +0000</pubDate>
				<category><![CDATA[Specs, Safety & Warranty]]></category>
		<category><![CDATA[Gen 1.3 Specs Safety and Warranty]]></category>
		<category><![CDATA[Gen 3 Specs Safety and Warranty]]></category>
		<guid isPermaLink="false">https://help.mistaway.com/misting-unit-spec-sheets/</guid>

					<description><![CDATA[<p>Gen 1.3 55 gal NO Agitation Includes remote control and waterproof cover. #90000:  120V/60 Hz Unit &#8211; Download spec sheet Gen 1.3 55 gal WITH Agitation Includes remote control and waterproof cover. #90155:  120V/60 Hz Unit &#8211; Download spec sheet #90851:  220V/50 Hz Unit &#8211; Download spec sheet Gen 1.3 55 gal WITH Agitation &#38; Leak Detection [&#8230;]</p>
<p>The post <a href="https://help.mistaway.com/misting-unit-spec-sheets/">Misting Unit Spec Sheets</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><span class="fontlargerred">Gen 1.3 55 gal NO Agitation</span></p>
<p><strong><span class="fontred"><img decoding="async" style="height: 200px; width: 200px;" src="https://help.mistaway.com/wp-content/uploads/2026/01/90000_90100_IMG_8570.jpg" alt="" /></span></strong></p>
<p>Includes remote control and waterproof cover.<br />
#90000:  120V/60 Hz Unit &#8211; <a href="https://help.mistaway.com/wp-content/uploads/1969/12/90000-Spec-Sheet-2019-02-06.pdf" target="_blank" rel="noopener">Download</a> spec sheet</p>
<p><span class="fontlargerred">Gen 1.3 55 gal WITH Agitation</span></p>
<p><strong><span class="fontred"><img decoding="async" style="width: 200px; height: 200px;" src="https://help.mistaway.com/wp-content/uploads/2026/01/90000_90100_IMG_8570.jpg" alt="" /></span></strong></p>
<p>Includes remote control and waterproof cover.<br />
#90155:  120V/60 Hz Unit &#8211; <a href="https://help.mistaway.com/wp-content/uploads/1969/12/90155-Spec-Sheet-2019-02-06.pdf" target="_blank" rel="noopener">Download</a> spec sheet<br />
#90851:  220V/50 Hz Unit &#8211; <a href="https://help.mistaway.com/wp-content/uploads/1969/12/90851-Spec-Sheet-2019-02-06.pdf" target="_blank" rel="noopener">Download</a> spec sheet</p>
<p><span class="fontlargerred">Gen 1.3 55 gal WITH Agitation &amp; Leak Detection</span></p>
<p><strong><span class="fontred"><img decoding="async" style="width: 200px; height: 200px;" src="https://help.mistaway.com/wp-content/uploads/2026/01/90000_90100_IMG_8570.jpg" alt="" /></span></strong></p>
<p>Includes remote control and waterproof cover.<br />
#80100:  120V/60 Hz Unit &#8211; <a href="https://help.mistaway.com/wp-content/uploads/1969/12/80100-Spec-Sheet-2019-02-06.pdf" target="_blank" rel="noopener">Download</a> spec sheet<br />
#81851:  220V/50 Hz Unit &#8211; <a href="https://help.mistaway.com/wp-content/uploads/1969/12/81851-Spec-Sheet-2019-02-06.pdf" target="_blank" rel="noopener">Download</a> spec sheet</p>
<p><span class="fontlargerred">Gen 1.3 125 gal WITH Agitation</span></p>
<p><strong><span class="fontred"><img decoding="async" style="width: 200px; height: 200px;" src="https://help.mistaway.com/wp-content/uploads/2026/01/90300_IMG_8641.jpg" alt="" /></span></strong><br />
Includes remote control and waterproof cover.  Ships on pallet.<br />
#90355:  120V/60 Hz Unit &#8211; <a href="https://help.mistaway.com/wp-content/uploads/1969/12/90355-Spec-Sheet-2019-02-06.pdf" target="_blank" rel="noopener">Download</a> spec sheet<br />
#90855:  High Flow (no remote) 120V/60 Hz Unit &#8211; <a href="https://help.mistaway.com/wp-content/uploads/1969/12/90855-Spec-Sheet-2019-02-06.pdf" target="_blank" rel="noopener">Download</a> spec sheet</p>
<p><span class="fontlargerred">Gen 1.3 125 gal WITH Agitation &amp; Leak Detection</span></p>
<p><strong><span class="fontred"><img decoding="async" style="width: 200px; height: 200px;" src="https://help.mistaway.com/wp-content/uploads/2026/01/90300_IMG_8641.jpg" alt="" /></span></strong><br />
Includes remote control and waterproof cover.  Ships on pallet.<br />
#80300:  120V/60 Hz Unit &#8211; <a href="https://help.mistaway.com/wp-content/uploads/1969/12/80300-Spec-Sheet-2019-02-06.pdf" target="_blank" rel="noopener">Download</a> spec sheet<br />
#90915:  High Flow 220V/50 Hz Unit &#8211; <a href="https://help.mistaway.com/wp-content/uploads/1969/12/90915-Spec-Sheet-2019-02-06pdf.pdf" target="_blank" rel="noopener">Download</a> spec sheet</p>
<p><span class="fontlargerred"><strong><span class="fontred">Gen 3+</span></strong></span></p>
<p><img decoding="async" style="width: 200px; height: 200px;" src="https://help.mistaway.com/wp-content/uploads/2026/01/90500_IMG_8710.jpg" alt="" /></p>
<p>Includes remote control, inlet water supply components, and Plus Cap for insecticide bottle<br />
#90500:  120V/60 Hz Unit &#8211; <a href="https://help.mistaway.com/wp-content/uploads/1969/12/90500-Spec-Sheet-2019-02-06.pdf" target="_blank" rel="noopener">Download</a> spec sheet<br />
#90854:  220V/50 Hz Unit &#8211; <a href="https://help.mistaway.com/wp-content/uploads/1969/12/90854-91854-Spec-Sheet-2019-02-06.pdf" target="_blank" rel="noopener">Download</a> spec sheet</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>The post <a href="https://help.mistaway.com/misting-unit-spec-sheets/">Misting Unit Spec Sheets</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Safety Certifications</title>
		<link>https://help.mistaway.com/safety-certifications/</link>
		
		<dc:creator><![CDATA[Homer Jon Young]]></dc:creator>
		<pubDate>Thu, 01 Jan 1970 00:00:00 +0000</pubDate>
				<category><![CDATA[Specs, Safety & Warranty]]></category>
		<category><![CDATA[Gen 1.3 Specs Safety and Warranty]]></category>
		<category><![CDATA[Gen 3 Specs Safety and Warranty]]></category>
		<guid isPermaLink="false">https://help.mistaway.com/safety-certifications/</guid>

					<description><![CDATA[<p>Gen 3 &#8211; 240V &#8211; 50/60Hz Tankless Misting Unit &#8211; #90854, #91854 Download EC Declaration of Conformity. Download IEC CB Test Certificate. Download Intertek Test Verification of CE Conformity. Gen 1.3 &#8211; 240V &#8211; 50/60Hz Drum Based Misting Unit &#8211; #90840, #90851, #81851, #90915 Download EC Declaration of Conformity. Download IEC CB Test Certificate. Download Intertek Test Verification [&#8230;]</p>
<p>The post <a href="https://help.mistaway.com/safety-certifications/">Safety Certifications</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><span class="fontlargerred">Gen 3 &#8211; 240V &#8211; 50/60Hz Tankless Misting Unit &#8211; #90854, #91854</span></p>
<p><img loading="lazy" decoding="async" class="" src="https://help.mistaway.com/wp-content/uploads/2026/01/90500_IMG_8710.jpg" alt="" width="389" height="389" /></p>
<p><a href="https://help.mistaway.com/wp-content/uploads/2026/01/MistAway-Gen-3-EC-DECLARATION-OF-CONFORMITY-90854-91854.pdf" target="_blank" rel="noopener">Download</a> EC Declaration of Conformity.<br />
<a href="https://help.mistaway.com/wp-content/uploads/2026/01/MistAway-Gen-3-CB-Certificate.pdf" target="_blank" rel="noopener">Download</a> IEC CB Test Certificate.<br />
<a href="https://help.mistaway.com/wp-content/uploads/2026/01/Mistaway-Test-Verification-of-Conformity-with-CE.pdf" target="_blank" rel="noopener">Download</a> Intertek Test Verification of CE Conformity.</p>
<p><span class="fontlargerred">Gen 1.3 &#8211; 240V &#8211; 50/60Hz Drum Based Misting Unit &#8211; #90840, #90851, #81851, #90915</span></p>
<p><img loading="lazy" decoding="async" class="" src="https://help.mistaway.com/wp-content/uploads/2026/01/90000_90100_IMG_8608.jpg" alt="" width="390" height="390" /></p>
<p><a href="https://help.mistaway.com/wp-content/uploads/2026/01/MistAway-Gen-1.3-EC-DECLARATION-OF-CONFORMITY-90840-90851-81851.pdf" target="_blank" rel="noopener">Download</a> EC Declaration of Conformity.<br />
<a href="https://help.mistaway.com/wp-content/uploads/2026/01/CB-Certificate-for-Gen-1.3-Misting-System.pdf" target="_blank" rel="noopener">Download</a> IEC CB Test Certificate.<br />
<a href="https://help.mistaway.com/wp-content/uploads/2026/01/Gen-1.3-Intertek-Test-Verification-of-Conformity-with-CE.pdf" target="_blank" rel="noopener">Download</a> Intertek Test Verification of CE Conformity</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>The post <a href="https://help.mistaway.com/safety-certifications/">Safety Certifications</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>