<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Controller &amp; Remote</title>
	<atom:link href="https://help.mistaway.com/category/controller-remote/feed/" rel="self" type="application/rss+xml" />
	<link>https://help.mistaway.com/category/controller-remote/</link>
	<description>MistAway TechSelfHelp</description>
	<lastBuildDate>Mon, 02 Feb 2026 20:27:10 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0.2</generator>

<image>
	<url>https://help.mistaway.com/wp-content/uploads/2026/02/cropped-MistAway-Help-Logo-32x32.png</url>
	<title>Controller &amp; Remote</title>
	<link>https://help.mistaway.com/category/controller-remote/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Gen 1.3 Controller:  Menus</title>
		<link>https://help.mistaway.com/gen-1-3-controller-menus/</link>
		
		<dc:creator><![CDATA[Homer Jon Young]]></dc:creator>
		<pubDate>Thu, 01 Jan 1970 00:00:00 +0000</pubDate>
				<category><![CDATA[Controller & Remote]]></category>
		<guid isPermaLink="false">https://help.mistaway.com/gen-1-3-controller-menus/</guid>

					<description><![CDATA[<p>Gen 1.3 SET-UP MENU REM  Set the duration for mists triggered by the remote transmitter.  (Values from OFF to 120 seconds) LRN  Program unit to recognize a specific remote transmitter.  Hold down Green ► button for 5 seconds and then press a button on the remote transmitter.  When DONE flashes in the display, the transmitter [&#8230;]</p>
<p>The post <a href="https://help.mistaway.com/gen-1-3-controller-menus/">Gen 1.3 Controller:  Menus</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><span class="fontred"><u><span class="fontlarger"><strong>Gen 1.3 SET-UP MENU</strong></span></u></span></p>
<p><span class="fontred"><strong>REM</strong></span>  Set the duration for mists triggered by the remote transmitter.  (Values from OFF to 120 seconds)</p>
<p><span class="fontred"><strong>LRN</strong></span>  Program unit to recognize a specific remote transmitter.  Hold down Green ► button for 5 seconds and then press a button on the remote transmitter.  When DONE flashes in the display, the transmitter is programmed.</p>
<p><strong><span class="fontred">MAN</span>*</strong>  Set the duration for mists triggered by a Manual Mist (pressing ▲ and ▼ buttons simultaneously.)<br />
NOZ  Set the Number of nozzles in the circuit attached to the unit.  If Zone Kit installed, there are separate displays for NZ1 and NZ2.</p>
<p><span class="fontred"><strong>AGT</strong></span>  Set duration in seconds of agitation prior to programmed mists and set time of once daily off-cycle agitation.  On units without an agitating valve, the duration should be set to 0.</p>
<p><strong><span class="fontred">RAG</span>  </strong> Set duration in seconds of agitation cycle prior to a remote mist cycle. (RAG not available on pre-2012 systems.)</p>
<p><span class="fontred"><strong>TNK</strong></span>  Set reservoir size in gallons (5 – 995)</p>
<p><span class="fontred"><strong>SEN</strong></span>  Turn (optional) wind sensor ON or OFF</p>
<p><span class="fontred"><strong>WND</strong></span>  Set max wind speed (above which wind sensor reading inhibits mist).</p>
<p><span class="fontred"><strong>ALT</strong></span>  This feature is not currently used. ALT should be set to 0.</p>
<p>* For systems with zone kit installed, see <u><a href="https://help.mistaway.com/gen-1-3-option-zone-kit/"><span class="fontblue">Gen 1.3 Option:  Zone Kit</span></a></u></p>
<p><span class="fontred"><u><span class="fontlarger"><strong>Gen 1.3 MAINTENANCE MENU</strong></span></u></span></p>
<p><strong><span class="fontred">LEVEL</span></strong>  Set the tank level in the controller display from 1 to 8 bars.  In operation, the indicated level will decrease as insecticide is misted.  Hold Green ► button for 5 seconds, then ▲ and ▼ buttons to set.</p>
<p><strong><span class="fontred">INS</span> </strong> Inspect Nozzle Circuit.  Runs pump for 5 minutes.  Hold Green ► button for 5 seconds to trigger.  If Zone Kit installed, separate inspection menus, INS1 and INS2.</p>
<p><span class="fontred"><u><span class="fontlarger"><strong>Gen 1.3 DATA MENU</strong></span></u></span></p>
<p><span class="fontred"><strong>TMC</strong></span>  Total Mist Cycles since last reset.* (*Reset by pressing <span class="fontsmaller">Green ► button until value shows zero)</span></p>
<p><span class="fontred"><strong>TMM</strong></span>  Total Mist Minutes since last reset.*</p>
<p><span class="fontred"><strong>MMC</strong>  </span>Manual Mist Cycles since last reset.*</p>
<p><span class="fontred"><strong>RMC</strong></span>  Remote Mist Cycles since last reset.*</p>
<p><span class="fontred"><strong>TMH</strong></span>  Total Mist Hours on unit.  May not be reset.</p>
<p><strong><span class="fontred">FL</span>**</strong>  Actual volume pumped out of tank during last mist (mL).</p>
<p><strong><span class="fontred">TF</span>**</strong>  Calculated target volume in milliliters (mL) of last mist. Target Volume = (Mist Duration in seconds) * (Number of Nozzles) * (Nozzle Flow Rate NFR) / 60.</p>
<p><span class="fontred"><strong>SPD</strong></span>  Wind speed as read by sensor.</p>
<p><strong><span class="fontred">AFR</span>**</strong>  Actual average flow rate of nozzle in circuit, based on volume of fluid discharged during last mist cycle.</p>
<p><strong><span class="fontred">TOL</span>**</strong>  Error tolerance for nozzle circuit flow rate.  Default is 75%.  Controls sensitivity of leak detection. (Set as per NFR).</p>
<p><span class="fontred"><strong>NFR</strong></span>  Target flow rate of average nozzle in circuit, in milliliters per minute.  Used in tank level indicator, Empty shut-off and leak detection calculations.  Default is 40 mL/min.  Set by pressing Green ► button for 5 seconds, then ▲ and ▼ arrows to adjust, then Green ► button to save.</p>
<p><span class="fontred"><strong>HLD</strong></span>  Duration that Agitating Valve or Anti-Siphon Valve remains open to nozzle circuit after pump shuts off. Used to control “at-rest” pressure maintained in circuit. (Set as per NFR).</p>
<p>** Visible only on units equipped with optional Leak Detection capability.</p>
<p><strong>NOTE:</strong> PAN, FR, NR and L menu items are for factory configuration only.</p>
<p>The post <a href="https://help.mistaway.com/gen-1-3-controller-menus/">Gen 1.3 Controller:  Menus</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Gen 3 Controller:  Menus</title>
		<link>https://help.mistaway.com/gen-3-controller-menus/</link>
		
		<dc:creator><![CDATA[Homer Jon Young]]></dc:creator>
		<pubDate>Thu, 01 Jan 1970 00:00:00 +0000</pubDate>
				<category><![CDATA[Controller & Remote]]></category>
		<guid isPermaLink="false">https://help.mistaway.com/gen-3-controller-menus/</guid>

					<description><![CDATA[<p>Gen 3 SET-UP MENU REM  Set the duration for mists triggered by the remote transmitter.  (Values from OFF to 120 seconds) LRN  Program unit to recognize a specific remote transmitter. Hold down Green ► button for 5 seconds and wait for countdown to begin. Press and hold any button on the remote transmitter. When DONE [&#8230;]</p>
<p>The post <a href="https://help.mistaway.com/gen-3-controller-menus/">Gen 3 Controller:  Menus</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><span class="fontred"><u><span class="fontlarger"><strong>Gen 3 SET-UP MENU</strong></span></u></span></p>
<p><strong><span class="fontred">REM</span></strong>  Set the duration for mists triggered by the remote transmitter.  (Values from OFF to 120 seconds)</p>
<p><span class="fontred"><strong>LRN</strong></span>  Program unit to recognize a specific remote transmitter.</p>
<ul>
<li>Hold down Green ► button for 5 seconds and wait for countdown to begin.</li>
<li>Press and hold any button on the remote transmitter.</li>
<li>When DONE flashes in the display, the transmitter is programmed.</li>
</ul>
<p><span class="fontred"><strong>MAN</strong></span><strong>*</strong>  Set the duration for mists triggered by a MANUAL MIST</p>
<p><span class="fontred"><strong>NOZ</strong></span><strong><span class="fontsmaller">*</span></strong>  Set the Number of nozzles in the circuit attached to the unit.  If Zone Kit installed, there are separate displays for NZ1 and NZ2.</p>
<p><span class="fontred"><strong>AGT</strong></span>  Set duration for agitation sequence prior to each AUTO mist.  Set time of once daily off-cycle agitation.</p>
<p><span class="fontred"><strong>RAG</strong></span>  Set duration for agitation prior to each REMOTE mist.</p>
<p><span class="fontred"><strong>SEN</strong></span>  Turn (optional) wind sensor ON or OFF</p>
<p><span class="fontred"><strong>WND</strong></span>  Set max wind speed (above which wind sensor reading inhibits mist.)</p>
<p><span class="fontred"><strong>ALT</strong></span>  Set time (in seconds) that (optional) external alarm will sound prior to each scheduled and remote mist</p>
<p><span class="fontred"><strong>ER0</strong></span>  Enable or disable ERRor Code 0.  Default is ON</p>
<p><span class="fontred"><strong>ER2</strong></span>  Enable or disable ERRor Code 2.  Default is OFF</p>
<p><span class="fontred"><strong>ER3</strong></span>  Enable or disable ERRor Code 3.  Default is ON</p>
<p><span class="fontred"><strong>ER6</strong></span>  Enable or disable ERRor Code 6.  Default is ON</p>
<p><span class="fontred"><strong>FM</strong></span>  Set flow meter type Brass (brS) or Plastic (PLS). Systems with serial numbers 403183 and higher are brass.</p>
<p>* For systems with zone kit installed, see <u><a href="https://help.mistaway.com/gen-3-option-zone-kit/"><span class="fontblue">Gen 3 Option:  Zone Kit</span></a></u></p>
<p><strong><span class="fontred"><u>Gen 3 MAINTENANCE MENU</u></span> </strong></p>
<p><span class="fontred"><b>REFILL</b></span>  “Virtually” fill the insecticide bottle.  Holding Green ► button for 5 seconds triggers routine that prompts user for insecticide/water MIX ratio, bottle size (in ounces), LEVEL of concentrate in bottle.</p>
<p><span class="fontred"><strong>DRN</strong></span>  Drain.  Unit will mist until batch tank is empty and pressure falls.  Hold Green ► button for 5 seconds to trigger.</p>
<p><span class="fontred"><strong>INS</strong></span>  Unit is in Inspection Mode.</p>
<ul>
<li>Unit will fill with water and then mist for 5 minutes (refilling as necessary) without adding insecticide.</li>
<li>Hold Green ► button for 5 seconds to trigger.  If a Zone Kit is installed, there are separate inspection menus, INS1 and INS2.</li>
</ul>
<p><span class="fontred"><strong>CHG</strong></span>  Adds a full charge of concentrate to the batch tank. Holding Green ► button for 5 seconds initiates an extended DOSE routine which brings the full batch of fresh water to its target MIX ratio.</p>
<p><span class="fontred"><strong>WINT</strong></span>  Winterizing step which holds inlet supply valve and agitation valve open for 30 seconds to allow any remaining trapped fluid to drain.  Hold Green ► button for 5 seconds to trigger.</p>
<p><span class="fontred"><strong>FLT</strong></span>  Float switch diagnostic.  Displays “dn” if float switch is not positioned at top of travel.  Displays “UP” if it is.  See <u><a href="https://help.mistaway.com/gen-3-run-float-switch-diagnostic/"><span class="fontblue">Gen 3:  Float Switch Test</span></a></u></p>
<p><span class="fontred"><strong>FL</strong> <strong>tst</strong></span>  Flowmeter Diagnostic. Holding Green ► button triggers routine that determines whether flow of water to the unit is normal and whether flowmeter is working as it should.  See <u><a href="https://help.mistaway.com/gen-3-run-flow-meter-diagnostic/"><span class="fontblue">Gen 3:  Flowmeter Test</span></a></u></p>
<p><span class="fontred"><span class="fontlarger"><strong><u>Gen 3 DATA MENU</u></strong></span></span></p>
<p><strong><span class="fontred">DM</span></strong>  Daily Mist time (cumulative, in seconds)</p>
<p><span class="fontred"><strong>MX</strong></span>  Maximum Daily Mist allowed (in seconds)</p>
<p><span class="fontred"><strong>TMC</strong></span>  Total Mist Cycles since last reset* (*Reset by pressing Green ► button until value shows zero.)</p>
<p><span class="fontred"><strong>TMM</strong></span>  Total Mist Minutes since last reset*</p>
<p><span class="fontred"><strong>MMC</strong></span>  MANUAL MIST Cycles since last reset*</p>
<p><span class="fontred"><strong>RMC</strong></span>  REMOTE MIST Cycles since last reset*</p>
<p><span class="fontred"><strong>TMH</strong></span>  Total Mist Hours on unit.  May not be reset.</p>
<p><span class="fontred"><strong>PRH</strong></span>  Cumulative dosing pump run time in hours.  May not be reset.</p>
<p><span class="fontred"><strong>SPD</strong></span>  Wind speed as read by sensor</p>
<p><span class="fontred"><strong>FL</strong></span>  Batch tank fill volume (in milliliters) following last mist</p>
<p><strong><span class="fontred">AFR</span> </strong> Average flow rate per nozzle in last zone misted (ml/min)</p>
<p><strong><span class="fontred">TF</span> </strong> Target fill volume (in milliliters)</p>
<p><span class="fontred"><strong>NFR</strong></span>  Flow rate of average nozzle in circuit (in ml/min).  Used in error condition calculations. Default is 45 ml/min.  Set by pressing Green ► button for 5 seconds, then ▲ and ▼ arrows, then Green ► button to save.</p>
<p><span class="fontred"><strong>NOZ</strong></span>  Number of nozzles in zone last misted</p>
<p><span class="fontred"><strong>TOL</strong></span>  Error tolerance in nozzle circuit flow rate.  Default is 80%.  See Adjusting Error Tolerance in Section 3.</p>
<p><span class="fontred"><strong>CF</strong></span>  Full cartridge volume (in milliliters)</p>
<p><strong><span class="fontred">CR</span> </strong> Remaining cartridge volume (in milliliters)</p>
<p><span class="fontred"><strong>DS</strong></span>  Dose volume (in milliliters)</p>
<p><span class="fontred"><strong>MIX</strong></span>  Current insecticide MIX ratio, expressed in Parts Water:Parts Insecticide</p>
<p><span class="fontred"><strong>DUE</strong></span>  Days Until Empty.  Remaining volume in cartridge, expressed in days of use until empty (Based on 14 day moving average consumption.  DUE reflecting first 14 days use will be inaccurate.)</p>
<p><span class="fontred"><strong>HLD</strong></span>  Time (in 0.1 seconds) that agitation valve is held open at end of mist cycle to allow pressure to decrease.  May be changed by pressing Green ► button for 5 seconds, then ▲ and ▼ arrows, then Green ► button to save.</p>
<div>* Reset by pushing Green ► button until value shows zero.</div>
<div>* <strong>PAN</strong>, <strong>FR</strong> and <strong>NR</strong> menu items are for iMistAway Module configuration.</div>
<div>* <strong>J</strong>, <strong>K</strong> and <strong>L</strong> menu items are for factory configuration only.</div>
<p>&nbsp;</p>
<p>The post <a href="https://help.mistaway.com/gen-3-controller-menus/">Gen 3 Controller:  Menus</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Controller:  &#8220;Learning&#8221; the iMist2-ready Handheld Remote Transmitter</title>
		<link>https://help.mistaway.com/controller-learning-the-imist2-ready-handheld-remote-transmitter/</link>
		
		<dc:creator><![CDATA[Homer Jon Young]]></dc:creator>
		<pubDate>Thu, 01 Jan 1970 00:00:00 +0000</pubDate>
				<category><![CDATA[Controller & Remote]]></category>
		<category><![CDATA[Gen 1.3 – Setup]]></category>
		<category><![CDATA[Gen 3 – Setup]]></category>
		<category><![CDATA[Gen 1.3 Programming]]></category>
		<category><![CDATA[Gen 1.3 Setup]]></category>
		<category><![CDATA[Gen 3 Programming]]></category>
		<category><![CDATA[Gen 3 Setup]]></category>
		<guid isPermaLink="false">https://help.mistaway.com/controller-learning-the-imist2-ready-handheld-remote-transmitter/</guid>

					<description><![CDATA[<p>The &#8220;iMist2-ready&#8221; handheld transmitter with the light colored label will communicate with the white &#8220;iMist2-ready&#8221; receiver but not with the first generation (black) receiver.    1.  Put the iMist2-ready receiver on the misting unit into &#8220;Learn&#8221; mode at the controller SET-UP Menu, LRT Press and hold Green ► button for 5 seconds until LRT is [&#8230;]</p>
<p>The post <a href="https://help.mistaway.com/controller-learning-the-imist2-ready-handheld-remote-transmitter/">Controller:  &#8220;Learning&#8221; the iMist2-ready Handheld Remote Transmitter</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><span style="font-size: 22px;"><span style="font-family: arial,helvetica,sans-serif;">The &#8220;iMist2-ready&#8221; handheld transmitter with the light colored label will communicate with the white &#8220;iMist2-ready&#8221; receiver but not with the first generation (black) receiver.</span></span></p>
<p><img decoding="async" style="height: 182px; width: 100px;" src="https://help.mistaway.com/wp-content/uploads/2026/01/imist2-remote-fron.jpg" alt="" /> <img decoding="async" style="width: 150px; height: 200px;" src="https://help.mistaway.com/wp-content/uploads/2026/01/imist2-receiver-mounted-on-chassis.jpg" alt="" /> <img decoding="async" style="width: 150px; height: 200px;" src="https://help.mistaway.com/wp-content/uploads/2026/01/imist2-node-on-Gen-3.jpg" alt="" /></p>
<div>
<p><span class="fontlargerred">1.  Put the iMist2-ready receiver on the misting unit into &#8220;Learn&#8221; mode at the controller</span></p>
<ul>
<li>SET-UP Menu, LRT</li>
<li>Press and hold Green ► button for 5 seconds until LRT is displayed and countdown starts</li>
</ul>
<p><img decoding="async" style="height: 146px; width: 150px;" src="https://help.mistaway.com/wp-content/uploads/2026/01/LRT-controller-screen.jpg" alt="" /> <img decoding="async" style="width: 150px; height: 143px;" src="https://help.mistaway.com/wp-content/uploads/2026/01/LRN-Controller-Scrn.jpg" alt="" /></p>
<p><span class="fontlargerred">2.  While the controller is counting down, put the handheld transmitter into &#8220;Learn&#8221; mode with a paper clip</span></p>
<ul>
<li>Pull the plastic &#8220;battery-save&#8221; protection tab (if present) from remote transmitter.</li>
<li>Use the supplied paperclip to press and quickly release the recessed pairing button on back of transmitter.  <span style="color: #ff0000;">DO NOT HOLD PAIRING BUTTON DOWN!</span></li>
<li>The blue LED above the button will flash several times, indicating it is in pairing mode</li>
<li>The controller display will indicate DONE when the transmitter and receiver are paired with each other.</li>
</ul>
<p>​<img decoding="async" style="width: 150px; height: 195px;" src="https://help.mistaway.com/wp-content/uploads/2026/01/Labeled-iM2-handheld-back.jpg" alt="" /> <img decoding="async" style="width: 125px;" src="https://help.mistaway.com/wp-content/uploads/2026/01/imist2-handheld-back-with-light.jpg" alt="" /></p>
<p><span class="fontlargerred">3.  If countdown continues without displaying DONE . . . </span></p>
<ul>
<li>In Step 2, if the pairing button is held down too long, the remote transmitter may have entered a frozen mode and will not pair with the receiver. You can tell if this has occurred by pressing (but not holding) the pairing button with the paper clip.  If the blue LED flashes twice, it is in the frozen mode.</li>
<li>If this has occurred, press and release the pairing button 4 times in succession.  On the 5th press, hold the button down for about 3 seconds.  While the button is pressed, the blue LED will be solid and then double blink.  After the double blink, release the button.</li>
<li>You should now be able to pair the transmitter and receiver by repeating step 2.</li>
</ul>
<p><span class="fontlargerred">4.  Confirm &#8220;Learn&#8221; by activating a remote mist cycle</span></p>
<ul>
<li>Confirm System Mode is set to REM or AUTO-Everyday</li>
<li>Confirm Level:  Gen1.3 &#8211; MAINTENANCE Menu, Level; Gen 3 &#8211; MAINTENANCE Menu, REFILL routine</li>
<li>Confirm number of nozzles:  SET-Up Menu, NOZ</li>
<li>Confirm remote mist duration:  SET-UP Menu, REM</li>
<li>Press MIST on handheld</li>
<li>LED on front of handheld will light when it receives confirming signal from iMist2-ready receiver on unit and unit will begin its mist cycle.</li>
</ul>
</div>
<p>To troubleshoot a remote that is not working, please visit our <a href="https://help.mistaway.com/unit-not-responding-to-command-from-white-remote-transmitter/" target="_blank" rel="noopener">Unit not responding to command from white remote transmitter</a> article for guidance.</p>
<p>The post <a href="https://help.mistaway.com/controller-learning-the-imist2-ready-handheld-remote-transmitter/">Controller:  &#8220;Learning&#8221; the iMist2-ready Handheld Remote Transmitter</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Controller:  &#8220;Learning&#8221; the 1st Generation Handheld Remote Transmitter</title>
		<link>https://help.mistaway.com/controller-learning-the-1st-generation-handheld-remote-transmitter/</link>
		
		<dc:creator><![CDATA[Homer Jon Young]]></dc:creator>
		<pubDate>Thu, 01 Jan 1970 00:00:00 +0000</pubDate>
				<category><![CDATA[Controller & Remote]]></category>
		<category><![CDATA[Gen 1.3 Programming]]></category>
		<category><![CDATA[Gen 3 Programming]]></category>
		<guid isPermaLink="false">https://help.mistaway.com/controller-learning-the-1st-generation-handheld-remote-transmitter/</guid>

					<description><![CDATA[<p>To ensure that another nearby transmitter will not accidentally activate the unit, the remote receiver can be configured to recognize a specific remote transmitter by changing the position of DIP switches on the transmitter prior to the LRN step. 1.  Open the transmitter and change the position of one or more DIP switches A.  The DIP switches are located [&#8230;]</p>
<p>The post <a href="https://help.mistaway.com/controller-learning-the-1st-generation-handheld-remote-transmitter/">Controller:  &#8220;Learning&#8221; the 1st Generation Handheld Remote Transmitter</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><span style="font-family: arial, helvetica, sans-serif; font-size: 22px;">To ensure that another nearby transmitter will not accidentally activate the unit, </span>the remote receiver can be configured to recognize a specific remote transmitter by changing the position of DIP switches on the transmitter prior to the LRN step.</p>
<div>
<p><strong><span class="fontred">1.  Open the transmitter and change the position of one or more DIP switches</span></strong></p>
<p>A.  The DIP switches are located on back of transmitter, on the side opposite the antenna, under a small plastic cover as shown.<br />
<img decoding="async" style="width: 300px; height: 200px;" src="https://help.mistaway.com/wp-content/uploads/2026/01/Remote_Transmitter_.jpg" alt="" /><br />
B.  Use the end of a pen to change the position of one or more of the switches, then replace cover.</p>
<p><strong><span class="fontred">2.  Orient Remote Transmitter</span></strong></p>
<ul>
<li>SET-UP Menu, LRN</li>
<li>Press and hold Green ► button for 5 seconds until LRN ON and countdown starts</li>
<li>Press and hold any button on the remote transmitter until DONE is displayed.</li>
</ul>
</div>
<p>&nbsp;</p>
<p>To troubleshoot a remote that is not working, please visit our <a href="https://help.mistaway.com/unit-not-responding-to-command-from-black-remote-transmitter/">Unit not responding to command from black remote transmitter</a> article for guidance.</p>
<p>The post <a href="https://help.mistaway.com/controller-learning-the-1st-generation-handheld-remote-transmitter/">Controller:  &#8220;Learning&#8221; the 1st Generation Handheld Remote Transmitter</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Controller:  Using the Remote</title>
		<link>https://help.mistaway.com/controller-using-the-remote/</link>
		
		<dc:creator><![CDATA[Homer Jon Young]]></dc:creator>
		<pubDate>Thu, 01 Jan 1970 00:00:00 +0000</pubDate>
				<category><![CDATA[Controller & Remote]]></category>
		<category><![CDATA[Gen 1.3 Programming]]></category>
		<category><![CDATA[Gen 3 Programming]]></category>
		<guid isPermaLink="false">https://help.mistaway.com/controller-using-the-remote/</guid>

					<description><![CDATA[<p>MIST Button Activates a REMOTE MIST for the duration defined in the SET-UP menu.  (SET-UP Menu, REM, Set duration in seconds) &#160; An agitation cycle may precede the REMOTE MIST, depending on the remote agitation duration configured in the SET-UP menu.  (SET-UP Menu, RAG, Set duration in seconds) &#160; If RAG is not available as [&#8230;]</p>
<p>The post <a href="https://help.mistaway.com/controller-using-the-remote/">Controller:  Using the Remote</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><span class="fontred"><span class="fontlarger"><strong>MIST Button</strong></span></span></p>
<ul>
<li>Activates a REMOTE MIST for the duration defined in the SET-UP menu.  (SET-UP Menu, REM, Set duration in seconds)</li>
</ul>
<p>&nbsp;</p>
<ul>
<li>An agitation cycle may precede the REMOTE MIST, depending on the remote agitation duration configured in the SET-UP menu.  (SET-UP Menu, RAG, Set duration in seconds)</li>
</ul>
<p>&nbsp;</p>
<ul>
<li>If RAG is not available as an option on the SET-UP menu, the system will agitate for 15 seconds prior to a REMOTE MIST.</li>
</ul>
<p>&nbsp;</p>
<ul>
<li>If a Zone Kit is installed, see <u><a href="https://help.mistaway.com/gen-1-3-option-zone-kit/"><span class="fontblue">Gen 1.3 Option:  Zone Kit</span></a></u> to configure how the remote transmitter works.</li>
</ul>
<p><span class="fontlarger"><span class="fontred"><strong>STOP MIST Button</strong></span></span></p>
<ul>
<li>The STOP MIST button stops the current operation of the unit. It will not change the System Mode from ON or AUTO to OFF.</li>
</ul>
<p><span class="fontred"><span class="fontlarger"><strong>SKIP NEXT MIST Button</strong></span></span></p>
<ul>
<li>The SKIP NEXT MIST button enables the next programmed AUTO MIST to be skipped.  The controller will display “SKIP.”</li>
</ul>
<p>&nbsp;</p>
<ul>
<li>While the unit is flashing SKIP, it will still respond to a Remote or MANUAL MIST.</li>
</ul>
<p>&nbsp;</p>
<ul>
<li>When an AUTO MIST has been skipped, the unit will return to the normal display, with a flashing “sunshine” icon in the lower right corner of the display.</li>
</ul>
<p>&nbsp;</p>
<ul>
<li>You may only skip one mist at a time.  That is, pushing the SKIP NEXT MIST button multiple times will not cause multiple AUTO MIST cycles to be skipped.</li>
</ul>
<p>&nbsp;</p>
<ul>
<li>Clear skip by holding down the ▲ button on the controller for 3 seconds.</li>
</ul>
<div></div>
<p>The post <a href="https://help.mistaway.com/controller-using-the-remote/">Controller:  Using the Remote</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Controller:  Navigation Guide</title>
		<link>https://help.mistaway.com/controller-navigation-guide/</link>
		
		<dc:creator><![CDATA[Homer Jon Young]]></dc:creator>
		<pubDate>Thu, 01 Jan 1970 00:00:00 +0000</pubDate>
				<category><![CDATA[Controller & Remote]]></category>
		<category><![CDATA[Gen 1.3 Programming]]></category>
		<category><![CDATA[Gen 3 Programming]]></category>
		<guid isPermaLink="false">https://help.mistaway.com/controller-navigation-guide/</guid>

					<description><![CDATA[<p>See the video at Installation &#8211; Navigating the Controller (1:50) Set System Mode On the home screen, which shows day and time, press Green ► button to position ▲at top of display to one of four System Modes: OFF &#8211; daily agitation cycle only. REM &#8211; Unit will allow Remote and Manual mists, but no AUTO-MISTs.  (Units [&#8230;]</p>
<p>The post <a href="https://help.mistaway.com/controller-navigation-guide/">Controller:  Navigation Guide</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>See the video at <a href="https://help.mistaway.com/installation-navigating-the-controller-150/">Installation &#8211; Navigating the Controller (1:50)</a></strong></p>
<p><img decoding="async" src="https://help.mistaway.com/wp-content/uploads/2026/01/Controller_Faceplate_Drawing.png" alt="" /></p>
<p><span class="fontlargerred">Set System Mode</span></p>
<p>On the home screen, which shows day and time, press Green ► button to position ▲at top of display to one of four System Modes:</p>
<ul>
<li><strong>OFF</strong> &#8211; daily agitation cycle only.</li>
<li><strong>REM</strong> &#8211; Unit will allow Remote and Manual mists, but no AUTO-MISTs.  (Units sold prior to 2012, Mode is ON)</li>
<li><strong>AUTO Everyday</strong> &#8211; Misting program runs daily.  <strong><span class="fontred">This is the most common System Mode.</span></strong></li>
<li><strong>AUTO Custom</strong> &#8211; mist program runs on days configured in CUSTOM PGM.</li>
</ul>
<p><span class="fontlargerred">Enter Menu Item</span></p>
<ul>
<li>Pressing Red MENU/STOP button displays triangular cursor, ►, by DAY/TIME position on left side of display.</li>
<li>Use ▲ and ▼ buttons to move through list of menu items &#8211; DAY/Time, CYCLES, SET-UP, MAINTENANCE, DATA</li>
<li>Use Green ► button to select menu item.</li>
</ul>
<p><span class="fontlargerred">View or Change Data in Menu Item</span></p>
<ul>
<li>A flashing data element can be changed with the ▲ and ▼ buttons.</li>
<li>Move to the next element with the Green ► button.</li>
<li>Exit the menu item by pressing the MENU button.</li>
<li>The value of the data element is automatically saved when you move to the next data element or exit.</li>
</ul>
<p><span class="fontlargerred">Initiate routine in Menu Item</span></p>
<ul>
<li>There are a number of routines that are initiated by pressing and holding the Green ► button for 5 seconds.</li>
<li>SET-UP Menu &#8211; LRN,</li>
<li>MAINTENANCE Menu &#8211; LEVEL (Gen 1.3), REFILL (Gen 3), CHG (Gen 3), WINT (Gen 3) INS, DRN</li>
<li>DATA Menu &#8211; TOL, HLD</li>
</ul>
<p><span class="fontlargerred">Clear Codes that have suspended operation of the unit</span></p>
<ul>
<li>ERRor codes &#8211; Clear by pressing and holding the Red MENU/Stop button for 5 seconds.</li>
<li>NOZ00 &#8211; Clear by pressing and holding the Red MENU/Stop button for 5 seconds.</li>
<li>SKIP (NEXT MIST) &#8211; Clear by pressing and holding the ▲ for 5 seconds.</li>
</ul>
<p><span class="fontlargerred">Reset controller to factory settings</span></p>
<ul>
<li>Unplug unit</li>
<li>Press and hold MENU and ▲ buttons simultaneously while restoring power to unit.</li>
<li>Mist cycles, remote duration and number of nozzles must be reentered.</li>
</ul>
<p>The post <a href="https://help.mistaway.com/controller-navigation-guide/">Controller:  Navigation Guide</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Controller:  Setting System Mode</title>
		<link>https://help.mistaway.com/controller-setting-system-mode/</link>
		
		<dc:creator><![CDATA[Homer Jon Young]]></dc:creator>
		<pubDate>Thu, 01 Jan 1970 00:00:00 +0000</pubDate>
				<category><![CDATA[Controller & Remote]]></category>
		<category><![CDATA[Gen 1.3 Programming]]></category>
		<category><![CDATA[Gen 3 Programming]]></category>
		<guid isPermaLink="false">https://help.mistaway.com/controller-setting-system-mode/</guid>

					<description><![CDATA[<p>Setting System Mode With the display showing day, time and level, press Green ► button to position the ▲ at top of display pointing to active System Mode. OFF &#8211; daily agitation cycle only ON &#8211; remote and manual, but no programmed mist AUTO Everyday &#8211; mist schedule runs daily.  This is the most common [&#8230;]</p>
<p>The post <a href="https://help.mistaway.com/controller-setting-system-mode/">Controller:  Setting System Mode</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><span class="fontlarger"><strong><span class="fontred">Setting System Mode</span></strong></span><br />
With the display showing day, time and level, press Green ► button to position the ▲ at top of display pointing to active System Mode.</p>
<p><strong>OFF</strong> &#8211; daily agitation cycle only</p>
<p><strong>ON</strong> &#8211; remote and manual, but no programmed mist</p>
<p><strong>AUTO Everyday</strong> &#8211; mist schedule runs daily.  <span class="fontred">This is the most common System Mode.</span></p>
<p><strong>AUTO Custom</strong> &#8211; mist program runs on days configured in CUSTOM PGM</p>
<p>The post <a href="https://help.mistaway.com/controller-setting-system-mode/">Controller:  Setting System Mode</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Controller:  Manual Mist</title>
		<link>https://help.mistaway.com/controller-manual-mist/</link>
		
		<dc:creator><![CDATA[Homer Jon Young]]></dc:creator>
		<pubDate>Thu, 01 Jan 1970 00:00:00 +0000</pubDate>
				<category><![CDATA[Controller & Remote]]></category>
		<category><![CDATA[Gen 1.3 Programming]]></category>
		<category><![CDATA[Gen 3 Programming]]></category>
		<guid isPermaLink="false">https://help.mistaway.com/controller-manual-mist/</guid>

					<description><![CDATA[<p>Press and hold the ▲&#160;and ▼ arrows simultaneously for 2 seconds&#160;to activate a mist cycle for the duration programmed for MAN in the SET-UP Menu.</p>
<p>The post <a href="https://help.mistaway.com/controller-manual-mist/">Controller:  Manual Mist</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p> <span><span>Press and hold the </span>▲&nbsp;and ▼ arrows simultaneously for 2 seconds&nbsp;to activate a mist cycle for the duration programmed for MAN in the SET-UP Menu.</span> </p>
<p>The post <a href="https://help.mistaway.com/controller-manual-mist/">Controller:  Manual Mist</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Controller:  Setting AUTO MIST Cycles</title>
		<link>https://help.mistaway.com/controller-setting-auto-mist-cycles/</link>
		
		<dc:creator><![CDATA[Homer Jon Young]]></dc:creator>
		<pubDate>Thu, 01 Jan 1970 00:00:00 +0000</pubDate>
				<category><![CDATA[Controller & Remote]]></category>
		<category><![CDATA[Gen 1.3 Programming]]></category>
		<category><![CDATA[Gen 3 Programming]]></category>
		<guid isPermaLink="false">https://help.mistaway.com/controller-setting-auto-mist-cycles/</guid>

					<description><![CDATA[<p>Set AUTO MIST Cycles 2 &#8211; 3 scheduled mists of 30-60 seconds in duration is common.  See Mist Schedule and Duration for field standard frequency, duration and mist times. CYCLES Menu Blinking C# identifies each automatic mist cycle with current mist duration and mist time.  Limit is 24 cycles per day. Set mist duration and time [&#8230;]</p>
<p>The post <a href="https://help.mistaway.com/controller-setting-auto-mist-cycles/">Controller:  Setting AUTO MIST Cycles</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong><span class="fontlarger"><span class="fontred">Set AUTO MIST Cycles</span></span></strong></p>
<ul>
<li>2 &#8211; 3 scheduled mists of 30-60 seconds in duration is common.  See <u><a href="https://help.mistaway.com/mist-schedule-and-duration/"><span class="fontblue">Mist Schedule and Duration</span></a></u> for field standard frequency, duration and mist times.</li>
<li>CYCLES Menu</li>
<li>Blinking C# identifies each automatic mist cycle with current mist duration and mist time.  Limit is 24 cycles per day.</li>
<li>Set mist duration and time (note AM/PM) for each desired scheduled mist.</li>
</ul>
<p><span class="fontlarger"><strong><span class="fontred">Set AUTO MIST Days &#8211; If you don&#8217;t want to schedule mists for every day</span></strong></span></p>
<ul>
<li>CUSTOM PGM Menu</li>
<li>Set selected days to ON or OFF</li>
<li>System Mode must be set to AUTO Custom.  See <u><a href="https://help.mistaway.com/controller-setting-system-mode/"><span class="fontblue">Controller:  Setting System Mode</span></a></u></li>
</ul>
<p>The post <a href="https://help.mistaway.com/controller-setting-auto-mist-cycles/">Controller:  Setting AUTO MIST Cycles</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Gen 3 Controller:  Status and External LED Displays</title>
		<link>https://help.mistaway.com/gen-3-controller-status-and-external-led-displays/</link>
		
		<dc:creator><![CDATA[Homer Jon Young]]></dc:creator>
		<pubDate>Thu, 01 Jan 1970 00:00:00 +0000</pubDate>
				<category><![CDATA[Controller & Remote]]></category>
		<guid isPermaLink="false">https://help.mistaway.com/gen-3-controller-status-and-external-led-displays/</guid>

					<description><![CDATA[<p>Gen 3 STATUS DISPLAYS AGT  Unit is agitating contents of batch tank. DOSE  Unit is adding insecticide to batch tank through dosing pump. DRN  Drain.  Unit will mist until batch tank is empty and pressure falls. FILL  Inlet supply valve is open and filling batch tank with water. HOLD  Agitation valve is being held open [&#8230;]</p>
<p>The post <a href="https://help.mistaway.com/gen-3-controller-status-and-external-led-displays/">Gen 3 Controller:  Status and External LED Displays</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><span class="fontlarger"><span class="fontred"><strong>Gen 3 STATUS DISPLAYS</strong></span></span></p>
<p><span class="fontred"><strong>AGT</strong></span>  Unit is agitating contents of batch tank.</p>
<p><span class="fontred"><strong>DOSE</strong></span>  Unit is adding insecticide to batch tank through dosing pump.</p>
<p><span class="fontred"><strong>DRN</strong></span>  Drain.  Unit will mist until batch tank is empty and pressure falls.</p>
<p><span class="fontred"><strong>FILL</strong></span>  Inlet supply valve is open and filling batch tank with water.</p>
<p><span class="fontred"><strong>HOLD</strong></span>  Agitation valve is being held open at end of mist cycle to allow pressure in nozzle circuit to decay and close nozzles quickly.</p>
<p><span class="fontred"><strong>INS</strong></span>  Unit is in Inspection Mode.  Unit will mist for 5 minutes or until stopped, refilling as necessary and without adding insecticide.</p>
<p><span class="fontred"><strong>MST</strong></span>  Unit is misting.</p>
<p><span class="fontred"><strong>SKIP</strong></span>  Unit will skip next programmed mist, having received signal from remote transmitter to SKIP NEXT MIST.  Clear by holding down the ▲ arrow button for 3 seconds.</p>
<p><span class="fontred"><strong>SUS</strong></span>  During 5 minute period following AUTO MIST, wind sensor is reading higher than user-set max and unit is suspending AUTO MIST.</p>
<p><span class="fontred"><strong>VENT</strong></span>  Prompt for user to vent the insecticide bottle by removing the cap from the top port and penetrating the bottle seal.  Loosely replace vent port cap.  Press Green ►button to continue.</p>
<p><span class="fontred"><strong>WRN</strong></span>  Unit is in warning period before misting.</p>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-9501" src="https://help.mistaway.com/wp-content/uploads/1969/12/flashing-sun.png" alt="" width="45" height="43" />  The previous mist was skipped because SKIP NEXT MIST was triggered by the remote or the wind sensor blocked an AUTO MIST.</p>
<p><span class="fontred"><u><span class="fontlarger"><strong>Gen 3 EXTERNAL LED DISPLAYS</strong></span></u></span></p>
<p><strong><span class="fontred">NO LIGHT</span>  </strong>Unit is idle.</p>
<p><strong><span class="fontred">RAPID FLASH</span>  </strong>Unit is about to mist and is either in the warning or agitate stage of the cycle.</p>
<p><strong><span class="fontred">SOLID LIGHT</span>  </strong>Unit is misting.</p>
<p><strong><span class="fontred">SLOW FLASH</span>  </strong>Either the cartridge is empty, a SKIP MIST has been triggered by the remote transmitter, or there is an error condition.</p>
<p>The post <a href="https://help.mistaway.com/gen-3-controller-status-and-external-led-displays/">Gen 3 Controller:  Status and External LED Displays</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>