<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Homer Jon Young, Author at TechSelfHelp</title>
	<atom:link href="https://help.mistaway.com/author/homerjongmail-com/feed/" rel="self" type="application/rss+xml" />
	<link>https://help.mistaway.com/author/homerjongmail-com/</link>
	<description>MistAway TechSelfHelp</description>
	<lastBuildDate>Wed, 13 May 2026 17:29:49 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0.3</generator>

<image>
	<url>https://help.mistaway.com/wp-content/uploads/2026/02/cropped-MistAway-Help-Logo-32x32.png</url>
	<title>Homer Jon Young, Author at TechSelfHelp</title>
	<link>https://help.mistaway.com/author/homerjongmail-com/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Legacy System Manuals and Support Resources</title>
		<link>https://help.mistaway.com/legacy-support-resources/</link>
		
		<dc:creator><![CDATA[Homer Jon Young]]></dc:creator>
		<pubDate>Tue, 13 Nov 2018 16:22:34 +0000</pubDate>
				<category><![CDATA[Parts & Assemblies]]></category>
		<category><![CDATA[Specs, Safety & Warranty]]></category>
		<category><![CDATA[Legacy Support]]></category>
		<guid isPermaLink="false">https://help.mistaway.com/?post_type=techselfhelparticles&#038;p=2207</guid>

					<description><![CDATA[<p>Note: Electronic Control parts for all legacy units are no longer available. Gen 1 / EFA Series Resources: Gen 1 / EFA Series Operating Manual &#160; Gen 1.2 Resources: Gen 1.2 Operating Manual &#160; Gen II Resources: Gen II Operating Manual</p>
<p>The post <a href="https://help.mistaway.com/legacy-support-resources/">Legacy System Manuals and Support Resources</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Note: Electronic Control parts for all legacy units are no longer available.</p>
<p><span class="fontlargerred" style="color: #ff0000;"><strong>Gen 1 / EFA Series Resources:</strong></span></p>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-2912" src="https://help.mistaway.com/wp-content/uploads/2018/12/gen1_efa.jpg" alt="" width="216" height="305" /></p>
<p><a href="https://help.mistaway.com/wp-content/uploads/2026/01/gen_1_manual.pdf">Gen 1 / EFA Series Operating Manual</a></p>
<p>&nbsp;</p>
<p><span class="fontlargerred" style="color: #ff0000;">Gen 1.2 Resources:</span></p>
<p><span class="fontlargerred" style="color: #ff0000;"><img loading="lazy" decoding="async" class="alignnone wp-image-2913" src="https://help.mistaway.com/wp-content/uploads/2018/12/gen1.2.jpg" alt="" width="219" height="310" /></span></p>
<p><a href="https://help.mistaway.com/wp-content/uploads/2026/01/Gen1_2_manual.pdf">Gen 1.2 Operating Manual</a></p>
<p>&nbsp;</p>
<p><span class="fontlargerred">Gen II Resources:</span></p>
<p><span class="fontlargerred"><img loading="lazy" decoding="async" class="alignnone wp-image-5648" src="https://help.mistaway.com/wp-content/uploads/2026/01/Screen-Shot-2020-07-16-at-12.14.40-PM.png" alt="genii" width="243" height="313" /></span></p>
<p><a href="https://help.mistaway.com/wp-content/uploads/2026/01/gen_ii_manual.pdf">Gen II Operating Manual</a></p>
<p>The post <a href="https://help.mistaway.com/legacy-support-resources/">Legacy System Manuals and Support Resources</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Gen 1.3:  Setup Checklist</title>
		<link>https://help.mistaway.com/gen-1-3-setup-checklist-part-1-of-3/</link>
		
		<dc:creator><![CDATA[Homer Jon Young]]></dc:creator>
		<pubDate>Thu, 01 Jan 1970 00:00:00 +0000</pubDate>
				<category><![CDATA[Gen 1.3 – Setup]]></category>
		<category><![CDATA[Gen 1.3 Setup]]></category>
		<guid isPermaLink="false">https://help.mistaway.com/gen-1-3-setup-checklist-part-1-of-3/</guid>

					<description><![CDATA[<p>To download and print the manual, click Gen 1.3 Manual. -1.  Pick a Suitable Location On firm level surface with good access for service. Free from flooding or sprinklers. Near GFCI outlet.  Unit&#8217;s power cord is 12 ft.  NEVER USE AN EXTENSION CORD! Unit requires 120V and 15 amp circuit.  Test with multi-meter. &#160; 0. [&#8230;]</p>
<p>The post <a href="https://help.mistaway.com/gen-1-3-setup-checklist-part-1-of-3/">Gen 1.3:  Setup Checklist</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>To download and print the manual, click <a href="https://help.mistaway.com/wp-content/uploads/2022/01/2020-08-Final-1-Sided-Gen-1.3-Manual.pdf" target="_blank" rel="noopener">Gen 1.3 Manual</a>.</p>
<p><span class="fontlargerred">-1.  Pick a Suitable Location</span></p>
<ul>
<li>On firm level surface with good access for service.</li>
<li>Free from flooding or sprinklers.</li>
<li>Near GFCI outlet.  Unit&#8217;s power cord is 12 ft.  <span style="color: #ff0000;">NEVER USE AN EXTENSION CORD!</span></li>
<li>Unit requires 120V and 15 amp circuit.  Test with multi-meter.</li>
</ul>
<p>&nbsp;</p>
<p><span class="fontlargerred">0.  Assemble the Unit</span></p>
<ul>
<li>Verify finish kit:
<ul>
<li>Remote transmitter</li>
<li>Soft drum lid cover</li>
<li>Pump suction tubing and filter</li>
<li>Auto-Drain Valve assembly</li>
<li>Agitator j-tube and mixing eductor (if agitated unit)</li>
<li>4 each &#8211; bolts, flat washers, lock washers, nuts</li>
</ul>
</li>
<li>Turn the unit upside down on towel to protect plastic housing.</li>
<li>Invert lid and rotate so that holes line up with fittings.</li>
<li>Insert lines into fittings:
<ul>
<li>1/2&#8243; Pump suction line into pump &#8211; <span style="color: #ff0000;">ENSURE IT IS SEATED!</span></li>
<li>1/4&#8243; Auto Drain Valve,</li>
<li>3/8&#8243; Agitation J-tube, if &#8220;with Agitator&#8221; unit</li>
</ul>
</li>
<li>Secure chassis to lid:
<ul>
<li>Sequence &#8211; bolt, chassis, lid, flat washer, lock washer, nut</li>
<li>Place and hand tighten all four connections</li>
<li>Tighten with 7/16&#8243; wrenches:</li>
</ul>
</li>
<li>Place lid assembly on drum.  Secure with gray drum ring.</li>
<li>For video, see Installation &#8211; <a href="https://learn.mistaway.com/courses/mistaway-university/lessons/lesson-7-working-with-the-misting-units/topics/7-2-setting-up-a-gen-1-3-drum-unit-1219/" target="_blank" rel="noopener">Setting Up a Gen 1.3 Drum Unit (12:19)</a></li>
</ul>
<p><span class="fontlargerred"><br />
1.  Test System and Inspect the Nozzle Circuit</span></p>
<ul>
<li>Connect nozzle circuit to 1/4&#8243; bulkhead fitting.</li>
<li>Install optional zone kit.  For instructions, see <a href="https://help.mistaway.com/gen-1-3-option-zone-kit/" target="_blank" rel="noopener noreferrer">Gen 1.3:  Zone Kit Installation</a></li>
<li>Plug unit into outlet and confirm controller boots up.</li>
<li>Fill drum through bung on lid and set level:
<ul>
<li>12-15 inches of water only.  <span style="color: #ff0000;">DO NOT ADD CONCENTRATE YET!</span></li>
<li>if 125 gallon drum unit, set TNK in SETUP Menu to 125.</li>
<li>Set gas gauge LEVEL in MAINTENANCE Menu to 2 bars.</li>
</ul>
</li>
<li>Inspect nozzle circuit for leaks
<ul>
<li>Run inspection cycle, INS in MAINTENANCE Menu.  System will pressure up and mist.</li>
<li>Check nozzle circuit for leaks and repair.</li>
<li>Repeat</li>
<li>If zone kit, inspect both zones with INS 1 and INS 2.</li>
</ul>
</li>
<li>Confirm pump pressure is 250 psi.
<ul>
<li>Run inspection cycle.</li>
<li>If necessary, adjust pump bypass with flathead screwdriver.  Port located back left corner of housing.</li>
</ul>
</li>
</ul>
<div></div>
<div>
<p><span class="fontlargerred">2.  Install the Nozzle Circuit Filter</span></p>
<ul>
<li>Mount filter head to bracket with screws.</li>
<li><span style="color: #ff0000;">FILL FILTER CANISTER WITH WATER!</span></li>
<li>Confirm o-ring on top of the canister is seated in groove, then screw filter housing onto the filter head.</li>
<li>Snap bracket and filter onto gray drum ring</li>
<li>Cut and connect 1/4&#8243; tubing following direction of flow arrows
<ul>
<li>Use enough tubing to be able set filter on ground during service</li>
<li>&#8220;IN&#8221; &#8211; misting unit to filter</li>
<li>&#8220;OUT&#8221; &#8211; filter to nozzle circuit</li>
</ul>
</li>
<li>For more details and photos, see <a href="https://help.mistaway.com/installing-nozzle-circuit-filter/" target="_blank" rel="noopener noreferrer">Installing Nozzle Circuit Filter</a></li>
</ul>
</div>
<p>&nbsp;</p>
<p><span class="fontlargerred">3.  Orient and Test the Handheld Remote Transmitter</span></p>
<ul>
<li>Set parameters in controller:
<ul>
<li>Set System Mode to Auto Everday on home screen</li>
<li>Set NOZ in SETUP Menu to nozzle count.  Set NOZ 1 and NOZ 2 if zone kit.</li>
<li>Set REM (remote mist duration) in SETUP Menu to desired.  45 secs is common.</li>
</ul>
</li>
<li>Put receiver in misting unit into &#8220;learn&#8221; mode
<ul>
<li>LRT in SET-UP Menu.  Press and hold green button</li>
<li>Countdown starts</li>
</ul>
</li>
<li>Put handheld transmitter in &#8220;learn&#8221; mode
<ul>
<li>Find recessed pairing button on back of transmitter</li>
<li>Use paperclip to press and quickly release button. <span style="color: #ff0000;">DO NOT HOLD PAIRING BUTTON DOWN!</span></li>
<li>Blue LED will flash several times</li>
<li>Controller will display &#8220;DONE&#8221;</li>
<li>Press MIST on handheld to complete pairing</li>
</ul>
</li>
<li>Test remote by pressing MIST.  Stop cycle by pressing STOP MIST</li>
<li>For more detail and troubleshooting, see <a href="https://help.mistaway.com/controller-learning-the-imist2-ready-handheld-remote-transmitter/" target="_blank" rel="noopener noreferrer">&#8220;Learning&#8221; the iMist2-ready Handheld Remote Transmitter</a></li>
</ul>
<p>&nbsp;</p>
<p><span class="fontlargerred">4.  Test Leak Detection</span></p>
<ul>
<li>Confirm the unit has leak detection option installed.  LD in DATA Menu will be ON</li>
<li>Press MIST on handheld transmitter and allow for a complete remote mist cycle</li>
<li>If controller displays ERR3, there is probably a leak.</li>
<li>Clear the error by pressing and holding Red Stop button and run another remote mist to confirm</li>
</ul>
<p>&nbsp;</p>
<p><span class="fontlargerred">5.  Add Concentrate, Top OFF Drum, Set Level to Full</span></p>
<ul>
<li>Unapproved concentrates may damage the system or may not be legal to apply through the system.  Make sure concentrate is in <a href="https://help.mistaway.com/gen-1-3-approved-insecticides/" target="_blank" rel="noopener noreferrer">Gen 1.3:  Approved Insecticides</a></li>
<li>Calculate required volume of concentrate:
<ul>
<li>Refer to label or link above for dosing instructions</li>
<li>Use <a href="https://help.mistaway.com/dosing-and-days-to-empty-calculators/" target="_blank" rel="noopener">Dosing and Days to Empty Calculator</a></li>
</ul>
</li>
<li>Use funnel to add concentrate to drum through bung on lid</li>
<li>Apply adhesive-backed label supplied with concentrate to side of drum</li>
<li>Fill drum with water to 3 inches from top.  Do not overfill.  Maintain 6&#8243; air gap between hose and fluid level.</li>
<li>Set gas gauge LEVEL in Maintenace Menu to full</li>
</ul>
<div>
<p>&nbsp;</p>
</div>
<p><span class="fontlargerred">6.  Set Mist Cycles</span></p>
<ul>
<li>Confirm day and time on home screen are correct.  If not, reset in DAY/TIME Menu.</li>
<li>Set mist duration and time for each cycle in CYCLES Menu.  24 possible daily mist cycles.</li>
<li>A common program is:
<ul>
<li>Morning:  around 7:00 am for 45 seconds (after sprinkler system has run)</li>
<li>Dusk:  around 7:00 pm for 45 seconds</li>
<li>Night:  around 11:00 pm for 45 seconds</li>
</ul>
</li>
<li>You may need to set other parameters in the SET-UP Menu (eg if you are installing a wind sensor).  You&#8217;ll find a complete list at <a href="https://help.mistaway.com/gen-1-3-controller-menus/" target="_blank" rel="noopener noreferrer">Gen 1.3 Controller:  Menus</a>  Otherwise, accept the defaults.</li>
</ul>
<p>&nbsp;</p>
<p><span class="fontlargerred">7.  Button Up the Unit</span></p>
<ul>
<li>Confirm System Mode set to Auto Everyday on home screen.</li>
<li>Put the waterproof cover over the unit, fitting the elastic at under the lip at the edge of the drum</li>
</ul>
<p>The post <a href="https://help.mistaway.com/gen-1-3-setup-checklist-part-1-of-3/">Gen 1.3:  Setup Checklist</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Gen 3:  Setup Checklist</title>
		<link>https://help.mistaway.com/gen-3-setup-checklist-part-1-of-3/</link>
		
		<dc:creator><![CDATA[Homer Jon Young]]></dc:creator>
		<pubDate>Thu, 01 Jan 1970 00:00:00 +0000</pubDate>
				<category><![CDATA[Gen 3 – Setup]]></category>
		<category><![CDATA[Gen 3 Setup]]></category>
		<guid isPermaLink="false">https://help.mistaway.com/gen-3-setup-checklist-part-1-of-3/</guid>

					<description><![CDATA[<p>The post <a href="https://help.mistaway.com/gen-3-setup-checklist-part-1-of-3/">Gen 3:  Setup Checklist</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="et_pb_section et_pb_section_0 et_section_regular" >
				
				
				
				
				
				
				<div class="et_pb_row et_pb_row_0">
								<div class="et_pb_column et_pb_column_4_4 et_pb_column_0  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_text et_pb_text_0  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner">To download and print the manual, click <a href="https://help.mistaway.com/wp-content/uploads/2026/01/gen_III_plus_one-sided_2011.pdf" target="_blank" rel="noopener noreferrer">Gen 3: Operating Manual</a></p>
<p><span class="fontlargerred">-1.  Pick a Suitable Location</span></p>
<ul>
<li>On firm level surface with good access for service.</li>
<li>Free from flooding or sprinklers.</li>
<li>Close to water faucet dedicated to the unit.  25 ft of 3/8&#8243; tubing included with unit.  Faucet must be able to deliver 1 gal/min.</li>
<li>Near GFCI outlet.  Unit&#8217;s power cord is 12 ft.  <span style="color: #ff0000;">NEVER USE AN EXTENSION CORD!</span></li>
<li>Unit requires 120V and 15 amp circuit.  Test with multi-meter.</li>
</ul>
<p>&nbsp;</p>
<p><span class="fontlargerred">0.  Remove Gen 3 from Box</span></p>
<ul>
<li>Open box and remove finish kit</li>
<li>Verify finish kit:
<ul>
<li>Remote transmitter</li>
<li>Antenna for remote receiver</li>
<li>Faucet adapter</li>
<li>25&#8242; of 3/8&#8243; tubing</li>
<li>inlet water filter with short length of 3/8&#8243; tubing</li>
<li>Plus Cap for concentrate bottle</li>
</ul>
</li>
<li>Lift unit straight up from box, placing one hand under front lip of the unit and the other hand on lip of open lid.</li>
<li>Thread remote antenna onto coax fitting on top of lid.</li>
</ul>
<p><span class="fontlargerred"><br />
1.  Connect the Water Supply Line</span></p>
<ul>
<li>Take care not to introduce dirt into the line.</li>
<li>Insert short length of 3/8&#8243; tubing connected to inlet water filter into 3/8&#8243; fitting on lower right corner of unit.</li>
<li>Thread faucet adapter onto faucet.  To allow Gen 3 to share faucet with garden hose, first connect a &#8220;Y&#8221; fitting with a valve on each leg.</li>
<li>Insert 3/8&#8243; line into faucet adapter, then measure and cut tubing.</li>
<li>Run water to flush line before connecting to filter port marked &#8220;IN.&#8221;</li>
</ul>
<p>&nbsp;</p>
<p><span class="fontlargerred">2.  Test the System and Inspect the Nozzle Circuit</span></p>
<ul>
<li>Connect nozzle circuit to 1/4&#8243; bulkhead fitting.</li>
<li>Install optional zone kit.  For instructions, see <a href="https://help.mistaway.com/gen-3-option-zone-kit/" target="_blank" rel="noopener noreferrer">Gen 3:  Zone Kit Installation</a></li>
<li>Plug unit into outlet and confirm controller boots up.</li>
<li>Inspect nozzle circuit for leaks
<ul>
<li>Run inspection cycle, INS in MAINTENANCE Menu.  After the batch tank fills with water, the system will pressure up and mist.</li>
<li>Check nozzle circuit for leaks and repair.</li>
<li>Repeat</li>
<li>If zone kit, inspect both zones with INS 1 and INS 2.</li>
</ul>
</li>
<li>Confirm pump pressure is 250 psi.
<ul>
<li>Run inspection cycle.</li>
<li>If necessary, adjust pump bypass with flathead screwdriver.  Port located back bottom left corner of unit.</li>
</ul>
</li>
</ul>
<div>
<p>&nbsp;</p>
<p><span class="fontlargerred">3.  Install the Nozzle Circuit Filter</span></p>
<ul>
<li>Mount filter head to bracket with screws, then mount filter head to right side of unit.</li>
<li><span style="color: #ff0000;">FILL FILTER CANISTER WITH WATER!</span></li>
<li>Confirm o-ring on top of the canister is seated in groove, then screw filter housing onto the filter head.</li>
<li>Cut and connect 1/4&#8243; tubing following direction of flow arrows
<ul>
<li>&#8220;IN&#8221; &#8211; misting unit to filter</li>
<li>&#8220;OUT&#8221; &#8211; filter to nozzle circuit</li>
</ul>
</li>
<li>For more details and photos, see <a href="https://help.mistaway.com/installing-nozzle-circuit-filter/" target="_blank" rel="noopener noreferrer">Installing Nozzle Circuit Filter</a></li>
</ul>
</div>
<p>&nbsp;</p>
<p><span class="fontlargerred">4.  Orient and Test the Handheld Remote Transmitter</span></p>
<ul>
<li>Set parameters in controller:
<ul>
<li>Run REFILL routine in the MAINTENANCE Menu.  <span style="color: #ff0000;">DO NOT INSERT CONCENTRATE BOTTLE!  </span>Accept defaults for MIX, BOT and LEVEL.  Press Green button after Vent to return to home screen.</li>
<li>Set System Mode to Auto Everday on home screen.</li>
<li>Set NOZ in SETUP Menu to nozzle count.  Set NOZ 1 and NOZ 2 if zone kit.</li>
<li>Set REM (remote mist duration) in SETUP Menu to desired.  45 secs is common.</li>
</ul>
</li>
<li>Put receiver in misting unit into &#8220;learn&#8221; mode
<ul>
<li>LRT in SET-UP Menu.  Press and hold green button</li>
<li>Countdown starts</li>
</ul>
</li>
<li>Put handheld transmitter in &#8220;learn&#8221; mode
<ul>
<li>Find recessed pairing button on back of transmitter</li>
<li>Use paperclip to press and quickly release button. <span style="color: #ff0000;">DO NOT HOLD PAIRING BUTTON DOWN!</span></li>
<li>Blue LED will flash several times</li>
<li>Controller will display &#8220;DONE&#8221;</li>
<li>Press MIST on handheld to complete pairing</li>
</ul>
</li>
<li>Test remote by pressing MIST.  Stop cycle by pressing STOP MIST</li>
<li>For more detail and troubleshooting, see <a href="https://help.mistaway.com/controller-learning-the-imist2-ready-handheld-remote-transmitter/" target="_blank" rel="noopener noreferrer">&#8220;Learning&#8221; the iMist2-ready Handheld Remote Transmitter</a></li>
</ul>
<p>&nbsp;</p>
<p><span class="fontlargerred">5.  Test Leak Detection</span></p>
<ul>
<li>Press MIST on handheld transmitter and allow for a complete remote mist cycle</li>
<li>If controller displays ERR3, there is probably a leak.</li>
<li>Clear the error by pressing and holding Red Stop button and run another remote mist to confirm</li>
</ul>
<p>&nbsp;</p>
<p><span class="fontlargerred">6.  Insert Concentrate Bottle and Charge the Batch Tank</span></p>
<ul>
<li>Unapproved concentrates may damage the system or may not be legal to apply through the system.  Make sure concentrate is in <a href="https://help.mistaway.com/gen-3-approved-insecticides/" target="_blank" rel="noopener noreferrer">Gen 3:  Approved Insecticides</a></li>
<li>Calculate required MIX ratio of concentrate (parts water: 1 part concentrate)
<ul>
<li>Refer to label or link above for dosing instructions</li>
<li>Use <a href="https://help.mistaway.com/dosing-and-days-to-empty-calculators/" target="_blank" rel="noopener">Dosing and Days to Empty Calculator</a></li>
</ul>
</li>
<li>Fill tip-and-measure bottle with concentrate:
<ul>
<li>Use a funnel</li>
<li>Do not cross-thread or overtighten Plus Cap on pour port</li>
<li>Remove seal from vent port</li>
<li>Apply adhesive-backed label supplied with concentrate to side of bottle</li>
</ul>
</li>
<li>Insert bottle into coupler</li>
<li>Run REFILL routine in the MAINTENANCE Menu
<ul>
<li>Enter calculated MIX ratio from above</li>
<li>Enter BOTtle size in ounces.  64 for 1/2 gallon bottle.  128 for 1 gallon bottle.</li>
<li>Set LEVEL to full</li>
<li>After VENT, press Green button to return to home screen</li>
</ul>
</li>
<li>Run CHG (Charge) routine in the MAINTENANCE Menu.  After it finishes, run it again.  <span style="color: #ff0000;">RUN TWO CHARGE CYCLES!</span></li>
</ul>
<div>
<p>&nbsp;</p>
</div>
<p><span class="fontlargerred">7.  Set Mist Cycles</span></p>
<ul>
<li>Confirm day and time on home screen are correct.  If not, reset in DAY/TIME Menu.</li>
<li>Set mist duration and time for each cycle in CYCLES Menu.  24 possible daily mist cycles.</li>
<li>A common program is:
<ul>
<li>Morning:  around 7:00 am for 45 seconds (after sprinkler system has run)</li>
<li>Dusk:  around 7:00 pm for 45 seconds</li>
<li>Night:  around 11:00 pm for 45 seconds</li>
</ul>
</li>
<li>You may need to set other parameters in the SET-UP Menu (eg if you are installing a wind sensor).  You&#8217;ll find a complete list at <a href="https://help.mistaway.com/gen-3-controller-menus/" target="_blank" rel="noopener noreferrer">Gen 3 Controller:  Menus</a>  Otherwise, accept the defaults.</li>
</ul>
<p>&nbsp;</p>
<p><span class="fontlargerred">8.  Button Up the Unit</span></p>
<ul>
<li>Confirm System Mode set to Auto Everyday on home screen.</li>
<li>Close lid on unit<u></u></li>
</ul></div>
			</div>
			</div>			
				
				
				
				
			</div>		
				
				
			</div>
<p>The post <a href="https://help.mistaway.com/gen-3-setup-checklist-part-1-of-3/">Gen 3:  Setup Checklist</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>New Commercial Riser Video</title>
		<link>https://help.mistaway.com/new-commercial-riser-video/</link>
		
		<dc:creator><![CDATA[Homer Jon Young]]></dc:creator>
		<pubDate>Thu, 01 Jan 1970 00:00:00 +0000</pubDate>
				<category><![CDATA[Nozzle Circuit]]></category>
		<guid isPermaLink="false">https://help.mistaway.com/new-commercial-riser-video/</guid>

					<description><![CDATA[<p>&#160;</p>
<p>The post <a href="https://help.mistaway.com/new-commercial-riser-video/">New Commercial Riser Video</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p> <center><iframe loading="lazy" allowfullscreen="" frameborder="0" height="300" mozallowfullscreen="" src="//player.vimeo.com/video/261220450" webkitallowfullscreen="" width="500"></iframe></p>
<p>
&nbsp;</center></p>
<p>The post <a href="https://help.mistaway.com/new-commercial-riser-video/">New Commercial Riser Video</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Gen 3: Controller displays EMP CAR and unit will not mist</title>
		<link>https://help.mistaway.com/gen-3-controller-displays-emp-car-and-unit-will-not-mist/</link>
		
		<dc:creator><![CDATA[Homer Jon Young]]></dc:creator>
		<pubDate>Thu, 01 Jan 1970 00:00:00 +0000</pubDate>
				<category><![CDATA[Gen 3 - Troubleshooting]]></category>
		<category><![CDATA[Gen 3 Troubleshooting]]></category>
		<guid isPermaLink="false">https://help.mistaway.com/gen-3-emp-car-flashing/</guid>

					<description><![CDATA[<p>Cause:  Unit has calculated zero remaining volume in the bottle and must be refilled. See Gen 3:  Refill Checklist &#160;</p>
<p>The post <a href="https://help.mistaway.com/gen-3-controller-displays-emp-car-and-unit-will-not-mist/">Gen 3: Controller displays EMP CAR and unit will not mist</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></description>
										<content:encoded><![CDATA[<ul>
<li>Cause:  Unit has calculated zero remaining volume in the bottle and must be refilled.</li>
<li>See <a href="https://help.mistaway.com/gen-3-refill-checklist/" target="_blank" rel="noopener">Gen 3:  Refill Checklist</a></li>
</ul>
<p>&nbsp;</p>
<p>The post <a href="https://help.mistaway.com/gen-3-controller-displays-emp-car-and-unit-will-not-mist/">Gen 3: Controller displays EMP CAR and unit will not mist</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Unit not misting automatically</title>
		<link>https://help.mistaway.com/unit-not-misting-automatically/</link>
		
		<dc:creator><![CDATA[Homer Jon Young]]></dc:creator>
		<pubDate>Thu, 01 Jan 1970 00:00:00 +0000</pubDate>
				<category><![CDATA[Gen 1.3 - Troubleshooting]]></category>
		<category><![CDATA[Gen 3 - Troubleshooting]]></category>
		<category><![CDATA[Gen 1.3 Troubleshooting]]></category>
		<category><![CDATA[Gen 3 Troubleshooting]]></category>
		<guid isPermaLink="false">https://help.mistaway.com/gen-1-3-auto-mist-not-working/</guid>

					<description><![CDATA[<p>Potential Causes:   System Mode is set to OFF or REM (or ON) and should be set to AUTO EVERYDAY or AUTO-CUSTOM. See Controller:  Setting System Mode There are no AUTO MIST cycles defined. See Controller:  Setting AUTO MIST Cycles The controller has calculated that the unit is empty and needs to be refilled. See Gen 1.3:  Controller displays EMP [&#8230;]</p>
<p>The post <a href="https://help.mistaway.com/unit-not-misting-automatically/">Unit not misting automatically</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><span class="fontlargerred">Potential Causes:  </span></p>
<ul>
<li>System Mode is set to OFF or REM (or ON) and should be set to AUTO EVERYDAY or AUTO-CUSTOM. See <a href="https://help.mistaway.com/controller-setting-system-mode/" target="_blank" rel="noopener noreferrer">Controller:  Setting System Mode</a></li>
<li>There are no AUTO MIST cycles defined. See <a href="https://help.mistaway.com/controller-setting-auto-mist-cycles/" target="_blank" rel="noopener noreferrer">Controller:  Setting AUTO MIST Cycles</a></li>
<li>The controller has calculated that the unit is empty and needs to be refilled.
<ul>
<li>See <a href="https://help.mistaway.com/gen-1-3-controller-displays-emp-and-unit-will-not-mist/" target="_blank" rel="noopener noreferrer">Gen 1.3:  Controller displays EMP and unit will not mist</a></li>
<li>See <a href="https://help.mistaway.com/gen-3-controller-displays-emp-car-and-unit-will-not-mist/" target="_blank" rel="noopener noreferrer">Gen 3:  Controller displays EMP CAR and unit will not mist</a></li>
</ul>
</li>
<li>Unit has suspended operating for some reason.  See <a href="https://help.mistaway.com/gen-1-3-noz00-and-will-not-mist/" target="_blank" rel="noopener noreferrer">Controller displays NOZ00, SKIP, ERR# or SUS and unit will not mist</a></li>
<li>The unit is plugged into the outlet but the display is blank.
<ul>
<li>See <a href="https://help.mistaway.com/gen-1-3-blank-controller-display/" target="_blank" rel="noopener noreferrer">Gen 1.3: Blank Controller Display</a></li>
<li>See <a href="https://help.mistaway.com/gen-3-blank-controller-display/" target="_blank" rel="noopener noreferrer">Gen 3: Blank Controller Display</a></li>
</ul>
</li>
</ul>
<p>The post <a href="https://help.mistaway.com/unit-not-misting-automatically/">Unit not misting automatically</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Controller:  &#8220;Learning&#8221; the iMist2-ready Handheld Remote Transmitter</title>
		<link>https://help.mistaway.com/controller-learning-the-imist2-ready-handheld-remote-transmitter/</link>
		
		<dc:creator><![CDATA[Homer Jon Young]]></dc:creator>
		<pubDate>Thu, 01 Jan 1970 00:00:00 +0000</pubDate>
				<category><![CDATA[Controller & Remote]]></category>
		<category><![CDATA[Gen 1.3 – Setup]]></category>
		<category><![CDATA[Gen 3 – Setup]]></category>
		<category><![CDATA[Gen 1.3 Programming]]></category>
		<category><![CDATA[Gen 1.3 Setup]]></category>
		<category><![CDATA[Gen 3 Programming]]></category>
		<category><![CDATA[Gen 3 Setup]]></category>
		<guid isPermaLink="false">https://help.mistaway.com/controller-learning-the-imist2-ready-handheld-remote-transmitter/</guid>

					<description><![CDATA[<p>The &#8220;iMist2-ready&#8221; handheld transmitter with the light colored label will communicate with the white &#8220;iMist2-ready&#8221; receiver but not with the first generation (black) receiver.    1.  Put the iMist2-ready receiver on the misting unit into &#8220;Learn&#8221; mode at the controller SET-UP Menu, LRT Press and hold Green ► button for 5 seconds until LRT is [&#8230;]</p>
<p>The post <a href="https://help.mistaway.com/controller-learning-the-imist2-ready-handheld-remote-transmitter/">Controller:  &#8220;Learning&#8221; the iMist2-ready Handheld Remote Transmitter</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><span style="font-size: 22px;"><span style="font-family: arial,helvetica,sans-serif;">The &#8220;iMist2-ready&#8221; handheld transmitter with the light colored label will communicate with the white &#8220;iMist2-ready&#8221; receiver but not with the first generation (black) receiver.</span></span></p>
<p><img decoding="async" style="height: 182px; width: 100px;" src="https://help.mistaway.com/wp-content/uploads/2026/01/imist2-remote-fron.jpg" alt="" /> <img decoding="async" style="width: 150px; height: 200px;" src="https://help.mistaway.com/wp-content/uploads/2026/01/imist2-receiver-mounted-on-chassis.jpg" alt="" /> <img decoding="async" style="width: 150px; height: 200px;" src="https://help.mistaway.com/wp-content/uploads/2026/01/imist2-node-on-Gen-3.jpg" alt="" /></p>
<div>
<p><span class="fontlargerred">1.  Put the iMist2-ready receiver on the misting unit into &#8220;Learn&#8221; mode at the controller</span></p>
<ul>
<li>SET-UP Menu, LRT</li>
<li>Press and hold Green ► button for 5 seconds until LRT is displayed and countdown starts</li>
</ul>
<p><img decoding="async" style="height: 146px; width: 150px;" src="https://help.mistaway.com/wp-content/uploads/2026/01/LRT-controller-screen.jpg" alt="" /> <img decoding="async" style="width: 150px; height: 143px;" src="https://help.mistaway.com/wp-content/uploads/2026/01/LRN-Controller-Scrn.jpg" alt="" /></p>
<p><span class="fontlargerred">2.  While the controller is counting down, put the handheld transmitter into &#8220;Learn&#8221; mode with a paper clip</span></p>
<ul>
<li>Pull the plastic &#8220;battery-save&#8221; protection tab (if present) from remote transmitter.</li>
<li>Use the supplied paperclip to press and quickly release the recessed pairing button on back of transmitter.  <span style="color: #ff0000;">DO NOT HOLD PAIRING BUTTON DOWN!</span></li>
<li>The blue LED above the button will flash several times, indicating it is in pairing mode</li>
<li>The controller display will indicate DONE when the transmitter and receiver are paired with each other.</li>
</ul>
<p>​<img decoding="async" style="width: 150px; height: 195px;" src="https://help.mistaway.com/wp-content/uploads/2026/01/Labeled-iM2-handheld-back.jpg" alt="" /> <img decoding="async" style="width: 125px;" src="https://help.mistaway.com/wp-content/uploads/2026/01/imist2-handheld-back-with-light.jpg" alt="" /></p>
<p><span class="fontlargerred">3.  If countdown continues without displaying DONE . . . </span></p>
<ul>
<li>In Step 2, if the pairing button is held down too long, the remote transmitter may have entered a frozen mode and will not pair with the receiver. You can tell if this has occurred by pressing (but not holding) the pairing button with the paper clip.  If the blue LED flashes twice, it is in the frozen mode.</li>
<li>If this has occurred, press and release the pairing button 4 times in succession.  On the 5th press, hold the button down for about 3 seconds.  While the button is pressed, the blue LED will be solid and then double blink.  After the double blink, release the button.</li>
<li>You should now be able to pair the transmitter and receiver by repeating step 2.</li>
</ul>
<p><span class="fontlargerred">4.  Confirm &#8220;Learn&#8221; by activating a remote mist cycle</span></p>
<ul>
<li>Confirm System Mode is set to REM or AUTO-Everyday</li>
<li>Confirm Level:  Gen1.3 &#8211; MAINTENANCE Menu, Level; Gen 3 &#8211; MAINTENANCE Menu, REFILL routine</li>
<li>Confirm number of nozzles:  SET-Up Menu, NOZ</li>
<li>Confirm remote mist duration:  SET-UP Menu, REM</li>
<li>Press MIST on handheld</li>
<li>LED on front of handheld will light when it receives confirming signal from iMist2-ready receiver on unit and unit will begin its mist cycle.</li>
</ul>
</div>
<p>To troubleshoot a remote that is not working, please visit our <a href="https://help.mistaway.com/unit-not-responding-to-command-from-white-remote-transmitter/" target="_blank" rel="noopener">Unit not responding to command from white remote transmitter</a> article for guidance.</p>
<p>The post <a href="https://help.mistaway.com/controller-learning-the-imist2-ready-handheld-remote-transmitter/">Controller:  &#8220;Learning&#8221; the iMist2-ready Handheld Remote Transmitter</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Active Ingredients Safety Fact Sheets</title>
		<link>https://help.mistaway.com/active-ingredients-safety-fact-sheets/</link>
		
		<dc:creator><![CDATA[Homer Jon Young]]></dc:creator>
		<pubDate>Thu, 01 Jan 1970 00:00:00 +0000</pubDate>
				<category><![CDATA[Concentrates]]></category>
		<category><![CDATA[Concentrate Safety]]></category>
		<category><![CDATA[Gen 1.3 Concentrate]]></category>
		<category><![CDATA[Gen 3 Concentrate]]></category>
		<guid isPermaLink="false">https://help.mistaway.com/active-ingredients-safety-fact-sheets/</guid>

					<description><![CDATA[<p>Pyrethrins (botanical), Permethrin (synthetic) and Piperonyl Butoxide (PBO) are the most common active ingredients found in mosquito misting formulations. Click on the links below to download National Pesticide Information Center (NPIC) fact sheets that answer questions about the effects of exposure to adults and children, links to cancer, and impact on the environment and wildlife. Pyrethrins Permethrin [&#8230;]</p>
<p>The post <a href="https://help.mistaway.com/active-ingredients-safety-fact-sheets/">Active Ingredients Safety Fact Sheets</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Pyrethrins (botanical), Permethrin (synthetic) and Piperonyl Butoxide (PBO) are the most common active ingredients found in mosquito misting formulations.</p>
<p>Click on the links below to download National Pesticide Information Center (NPIC) fact sheets that answer questions about the effects of exposure to adults and children, links to cancer, and impact on the environment and wildlife.</p>
<p><a href="https://npic.orst.edu/factsheets/pyrethrins.html"><span class="fontblue"><u>Pyrethrins</u></span></a></p>
<p><a href="https://npic.orst.edu/factsheets/PermGen.html"><span class="fontblue"><u>Permethrin</u></span></a></p>
<p><a href="https://npic.orst.edu/factsheets/pbogen.pdf"><span class="fontblue"><u>Piperonyl Butoxide</u></span></a></p>
<p>&nbsp;</p>
<p>The post <a href="https://help.mistaway.com/active-ingredients-safety-fact-sheets/">Active Ingredients Safety Fact Sheets</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>System Design Process &#8211; Training Videos</title>
		<link>https://help.mistaway.com/training-videos-installation-planning/</link>
		
		<dc:creator><![CDATA[Homer Jon Young]]></dc:creator>
		<pubDate>Thu, 01 Jan 1970 00:00:00 +0000</pubDate>
				<category><![CDATA[Uncategorized]]></category>
		<guid isPermaLink="false">https://help.mistaway.com/training-videos-installation-planning/</guid>

					<description><![CDATA[<p>An effective mosquito misting system starts with a good plan.  The videos in this article describe the design process and the factors you should consider as you work through it. System Design Guidelines Design a “perimeter of protection.” Place nozzles ten feet apart. Consider the prevailing wind. Use interior nozzles if the perimeter is large. [&#8230;]</p>
<p>The post <a href="https://help.mistaway.com/training-videos-installation-planning/">System Design Process &#8211; Training Videos</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>An effective mosquito misting system starts with a good plan.<span class="Apple-converted-space">  </span>The videos in this article describe the design process and the factors you should consider as you work through it.</p>
<p><b>System Design Guidelines</b></p>
<ol>
<li>Design a “perimeter of protection.”</li>
<li>Place nozzles ten feet apart.</li>
<li>Consider the prevailing wind.</li>
<li>Use interior nozzles if the perimeter is large.</li>
<li>Place nozzles 8 feet apart in areas requiring more treatment.</li>
<li>Don’t put nozzles too near the water, koi ponds or on or near jungle gyms or swing sets.</li>
<li>Avoid installing nozzles over 10 feet high.</li>
<li>Avoid installing nozzles at the top of a fence.</li>
<li>Place landscape risers at least two feet from plants.</li>
<li>Protect tubing in ground transitions with conduit.</li>
<li>Place the unit on a flat surface near water and power, so it is accessible and protected from rain and sprinklers.</li>
</ol>
<p>&nbsp;</p>
<p><span class="fontlargerred">System Design Part 1 (8:47)</span></p>
<p><center><iframe loading="lazy" src="//player.vimeo.com/video/146416509" width="500" height="300" frameborder="0" allowfullscreen="allowfullscreen"></iframe></center>&nbsp;</p>
<p><span class="fontlargerred">System Design Part 2 (9:14)</span></p>
<p><center><iframe loading="lazy" src="//player.vimeo.com/video/146417171" width="500" height="300" frameborder="0" allowfullscreen="allowfullscreen"><span data-mce-type="bookmark" style="display: inline-block; width: 0px; overflow: hidden; line-height: 0;" class="mce_SELRES_start">﻿</span></iframe></center>&nbsp;</p>
<p>The post <a href="https://help.mistaway.com/training-videos-installation-planning/">System Design Process &#8211; Training Videos</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Gen 3:  Replace Pressure Gauge</title>
		<link>https://help.mistaway.com/gen-3-replace-pressure-gauge/</link>
		
		<dc:creator><![CDATA[Homer Jon Young]]></dc:creator>
		<pubDate>Thu, 01 Jan 1970 00:00:00 +0000</pubDate>
				<category><![CDATA[Gen 3 Repairs]]></category>
		<guid isPermaLink="false">https://help.mistaway.com/gen-3-replace-pressure-gauge/</guid>

					<description><![CDATA[<p>Time:  15 minutes Tools: 15 mm wrench crescent wrench or channel lock pliers 5/16&#8243; nut driver Teflon tape snip for zip tie and small zip tie paper towels to blot concentrate Parts: Replacement Pressure Gauge Assembly &#8211; Includes Gauge and Fitting (SKU 21037) 1.  Remove bottle.  Reposition controller and shroud.  See Gen 3:  Access Components by [&#8230;]</p>
<p>The post <a href="https://help.mistaway.com/gen-3-replace-pressure-gauge/">Gen 3:  Replace Pressure Gauge</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><span class="fontgreen"><img decoding="async" style="width: 300px; height: 400px;" src="https://help.mistaway.com/wp-content/uploads/2026/01/Gen3_Pressure_Gauge.jpg" alt="" /></span></p>
<p><strong>Time:  </strong>15 minutes<br />
<strong>Tools:</strong></p>
<ul>
<li>15 mm wrench</li>
<li>crescent wrench or channel lock pliers</li>
<li>5/16&#8243; nut driver</li>
<li>Teflon tape</li>
<li>snip for zip tie and small zip tie</li>
<li>paper towels to blot concentrate</li>
</ul>
<p><strong>Parts:</strong></p>
<ul>
<li>Replacement Pressure Gauge Assembly &#8211; Includes Gauge and Fitting (SKU 21037)</li>
</ul>
<p><span class="fontlarger"><span class="fontred"><strong>1.  Remove bottle.  Reposition controller and shroud.  </strong></span>See <a href="https://help.mistaway.com/gen-3-access-components-by-repositioning-shroud/" target="_blank" rel="noopener"><span class="fontblue"><u>Gen 3:  Access Components by Repositioning Shroud</u></span></a>.</span></p>
<p><span class="fontred"><strong>2.  Remove existing pressure gauge</strong></span></p>
<p>A.  Cut zip tie securing flexible tubing to coupler.  Put on latex gloves and remove tubing.  Allow concentrate in tubing to drain onto paper towel.<br />
<span class="fontgreen"><img decoding="async" style="width: 300px; height: 200px;" src="https://help.mistaway.com/wp-content/uploads/2026/01/G3_Coupler_Tubing_Ziptie.jpg" alt="" /></span></p>
<p>B.  Remove 1/4&#8243; nylon tubing from fitting on pressure gauge and remove shroud from unit.</p>
<p>C.  Using channel locks or crescent wrench and 15 mm wrench, remove straight female connector as shown.<br />
<img decoding="async" style="width: 300px; height: 200px;" src="https://help.mistaway.com/wp-content/uploads/2026/01/Gen13_Pressure_Wrenches.jpg" alt="" /></p>
<p>D.  Using 5/16&#8243; nut driver to remove nuts securing gauge to bracket, and remove the gauge from shroud.</p>
<p><span class="fontlarger"><span class="fontred"><strong>3.  Install replacement gauge</strong></span></span></p>
<p>A.  Wrap teflon tape around threads on gauge.<br />
<img decoding="async" style="width: 300px; height: 200px;" src="https://help.mistaway.com/wp-content/uploads/2026/01/Pressure_Teflon_tape.jpg" alt="" /></p>
<p>B.  If the diameter of the failed gauge (and the hole it was mounted in) is the same size as the new gauge, proceed to step 3D.  if not, you&#8217;ll need to use the adapter rings.</p>
<p>C.  Slide one of the adapter rings over the gauge, then insert the gauge into the hole, so that the ring is between the gauge and the top side of the shroud. Slide the other adapter ring over the gauge, sandwiching the gauge between the two rings.<br />
<span class="fontgreen"><img decoding="async" style="width: 300px; height: 400px;" src="https://help.mistaway.com/wp-content/uploads/2026/01/Gen3_Pressure_Plates.jpg" alt="" /></span></p>
<p>D.  Position the bracket on the back of the gauge and then tighten the straight female connector to the gauge.</p>
<p>E.  Ensure the gauge is oriented correctly on the top side of the shroud, then tighten the nuts securing the gauge to the shroud.</p>
<p>F.  Place shroud with new gauge on left side of unit and reconnect 1/4&#8243; nylon tubing to gauge. Make sure it is secure in the fitting.</p>
<p>G.  Reconnect flexible tubing that feeds dosing pump to hose barb on coupler and secure with zip tie.</p>
<p><span class="fontlarger"><span class="fontred"><strong>4.  Return shroud and controller to original position. </strong></span></span><strong> See <a href="https://help.mistaway.com/gen-3-access-components-by-repositioning-shroud/" target="_blank" rel="noopener">Gen 3:  Access Components by Repositioning Shroud</a>.</strong></p>


<p class="wp-block-paragraph"></p>
<p>The post <a href="https://help.mistaway.com/gen-3-replace-pressure-gauge/">Gen 3:  Replace Pressure Gauge</a> appeared first on <a href="https://help.mistaway.com">TechSelfHelp</a>.</p>